User Information
Load-bearing tower Staxo 40
System description
25
999805002 - 09/2018
Extending the range of use with brackets
Staxo 40 bracket 90cm
Conditions applying to use
Assembly
1)
Secure tower (e.g. with a plumbing strut) so that it
cannot tip over.
2)
Install a Staxo 40 frame strut 1.40m if the pull-point
or pressure point of the bracket is not supported.
3)
Bolt the Staxo 40 bracket 90cm to the top of the
diagonal tube of the frame and secure the bolt.
Insert and secure the bottom bolt, to prevent acci-
dental lift-out.
➤
Fit Diagonal crosses 9.xxx between the brackets and
secure them with safety catches
Extension with Handrail post
XP
1.20m
Extension with Staxo 40 screw-
jack U-heads / 4-way screw-jack
heads
WARNING
Risk of tipping over!
➤
Before setting up and using the bracket,
secure the tower with plumbing struts or tie-
backs so that it cannot tip over.
NOTICE
Bracing with a Staxo 40-frame strut 1.40m is
always required if the pull-point or pressure
point of the bracket is not supported.
The integrated swivel unit on the Staxo 40-
frame strut 1.40m also makes it possible to
retro-fit it to a previously erected tower unit.
98024-263-01
98024-263-03
98024-263-02
A
Staxo
40 bracket 90cm
D
Staxo
40 frame
E
Staxo 40 frame strut 1.40m (if needed)
Q
Pin D16/122
R
Linch pin 6x42
98024-274-01
A
D
E
Q
R
98024-280-01