User Information
Load-bearing tower Staxo 40
System description
11
999805002 - 09/2018
Diagonal crosses (C)
Base units (D)
Scaffold planking units (E)
Drop-in steel-tube bracing crosses
between the frames.
Identified by:
▪
Embossed marking
(G)
e.g.
18.250
- 18 = frame height 1.80
m
- 250 = inter-frame spacing
250
cm
▪
Notched, colour-coded clips
(H)
(see table)
Designation
Colour-coded
clip
Notches
Diagonal cross 9.100
Green
—
Diagonal cross 9.150
Red
—
Diagonal cross 9.175
Light green
—
Diagonal cross 9.200
Blue
—
Diagonal cross 9.250
Yellow
—
Diagonal cross 9.300
Orange
—
Diagonal cross 12.100
Green
1
Diagonal cross 12.150
Red
1
Diagonal cross 12.175
Light green
1
Diagonal cross 12.200
Blue
1
Diagonal cross 12.250
Yellow
1
Diagonal cross 12.300
Orange
1
Diagonal cross 18.100
Green
3
Diagonal cross 18.150
Red
3
Diagonal cross 18.175
Light green
3
Diagonal cross 18.200
Blue
3
Diagonal cross 18.250
Yellow
3
Diagonal cross 18.300
Orange
3
Basic rule:
To maintain correct geometry, horizontally placed
Diagonal crosses 12.xxx or shear-rigid planking units
must be fitted in the following cases:
▪
in the bottom and top 'storeys'
▪
every 10 m
▪
in between as required, e.g. where
- there is a horizontal restraint for the tower
(even a temporary one)
- local loads need to be transferred (e.g. from a
bracket or from attaching the tower to the crane
when it is assembled in the horizontal)
G
H
98024-205-01
C
Staxo 40 screw-jack foot 30cm
Staxo 40 screw-jack foot 70cm
Scaffold planking 30/...cm
Scaffold planking 60/...cm with
manhole
Steel scaffold planking units for
making safe assembly decks.
Aluminium/timber scaffold plank-
ing units with self-closing cover,
for making safe assembly decks.
Integral anti-liftout guard
Width: 30
cm
Width: 60
cm
Lengths: 100 / 150 / 175 / 200 / 250 / 300
cm
Permitted service load: 1.5
kN/m
2
(150 kg/m
2
)
Load Class 2 to EN 12811-1:2003