User Information
Load-bearing tower Staxo 40
Assembling towers in the upright
45
999805002 - 09/2018
➤
Mount the Staxo front railings.
Close-up of how to hang into place
➤
Insert Staxo 40 couplers.
Note:
If it is intended to crane-lift the tower, the frames must
all be linked in a crane-handling-safe manner by
Staxo
40 tube connectors D48.3mm. See also the sec-
tion entitled 'Lifting by crane'.
Erecting the second storey
Stacking the frames
➤
Add the next frames.
➤
Push diagonal crosses onto the safety-catch bolts
and secure them with the safety catches.
➤
Hook in the ladder and secure with Spring cotters d6.
Close-up of ladder (as seen from the inside of the
load-bearing tower)
M
Staxo front railing
980 - -01
24 312
M
M
98024-326-02
98024-326-03
98024-213-02
F
Diagonal cross
N
Staxo 40/d3 ladder 2.30m
980 - -01
24 320
F
N
98024-327-01