© 2001 Directed Electronics, Inc. Vista, CA
3
primary harness (H1), 12-pin connector
___
___
___
___
___
___
___
___
___
___
___
___
This guide describes in detail the connection of each wire. Also included are possible applications of each wire.
This system was designed with the ultimate in flexibility and security in mind. Many of the wires have more than
one possible function. Please read the instructions carefully to ensure a thorough understanding of this system
and how it operates.
H1/1 ORANGE (-) GROUND-WHEN-ARMED OUTPUT
This wire supplies a (-) ground as long as the system is armed. This output ceases as soon as the system is
disarmed. The orange wire is pre-wired to control the P/N
8618
starter kill relay. It can supply up to 500 mA of
current.
NOTE:
If connecting the orange wire to control another module, such as a P/N
529T
or P/N
530T
window module, a 1 amp diode (type 1N4004) will be required. (See the following diagram.)
primary harness wiring guide
RED/WHITE
OUTPUT OF CHANNEL 2 RELAY #30
RED
(+) 12V CONSTANT POWER INPUT
BROWN
(+) SIREN OUTPUT
YELLOW
(+) SWITCHED IGNITION INPUT, ZONE 8
BLACK
(-) CHASSIS GROUND INPUT
VIOLET
(+) DOOR TRIGGER INPUT, ZONE 3
BLUE
(-) INSTANT TRIGGER INPUT, ZONE 1
GREEN
(-) DOOR TRIGGER INPUT, ZONE 3
BLACK/WHITE
OUTPUT OF DOMELIGHT SUPERVISION RELAY #30
WHITE/BLUE
(-) 200 mA CHANNEL 3 PROGRAMMABLE OUTPUT
WHITE
(+/-) SELECTABLE LIGHT FLASH OUTPUT
ORANGE
(-) 500 mA GROUND-WHEN-ARMED OUTPUT
H1/1
H1/2
H1/3
H1/4
H1/5
H1/6
H1/7
H1/8
H1/9
H1/10
H1/11
H1/12
primary harness wiring diagram