![Directed Electronics Python 3000 ESP Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/directed-electronics/python-3000-esp/python-3000-esp_installation-manual_2507211018.webp)
18
© 2001 Directed Electronics, Inc. Vista, CA
auxiliary output harness (H3), 11-pin connector
___
___
___
___
___
___
___
___
___
___
___
H3/1 GREEN/BROWN (-) MULTIPLEX SENSOR INPUT
This multiplexed input is capable of triggering either the Warn Away response or the triggered sequence. Inputs
that are shorter than 0.8 seconds will only trigger Warn Away. The first stage of DEI dual stage sensors supplies
this type of pulse. Inputs that are longer than 0.8 seconds will trigger the full alarm cycle. The full trigger will
report on Zone 4 and the Warn Away will report on Zone 6.
H3/2 BROWN/BLACK (-) SENSOR SHUNT INPUT
When ground is applied to this wire, all sensors will be bypassed. The only inputs capable of triggering the system
while this wire is grounded are the door trigger and the ignition. After ground is removed, the system will begin
responding to sensors after 5 seconds. During the 5 second recovery period, an input from any sensor will reset
the 5-second recovery timer. This wire can be used to bypass sensors for remote starting, window roll up, etc.
PROGRAMMABLE OUTPUTS
The outputs for Channels 4 (H3/3), 5 (H3/4) and 6 (H3/5) are programmable. Each of the outputs supplies
200 mA of current and cannot directly drive high current circuits. Selectability allows the installer to configure
the system for a wide range of applications. The four types of outputs that are available are:
auxiliary output harness wiring guide
PINK/BLACK
(-) DELAYED ACCESSORY OUTPUT
BLACK/WHITE
IGNITION LOCK SAFETY INPUT
ORANGE/BLACK
(+) GHOST SWITCH INPUT
GREEN
(-) 200 mA FACTORY SECURITY DISARM OUTPUT
BLUE
(-) 200 mA SECOND UNLOCK/CHANNEL 7
BROWN
(-) 200 mA HORN HONK OUTPUT
WHITE/BLACK
(-) 200 mA CHANNEL 6 OUTPUT
GRAY/BLACK
(-) 200 mA CHANNEL 5 OUTPUT
PURPLE/BLACK
(-) 200 mA CHANNEL 4 OUTPUT
BROWN/BLACK
(-) SENSOR SHUNT INPUT
GREEN/BROWN
(-) SENSOR INPUT MULTIPLEX ZONES 4 AND 6
H3/1
H3/2
H3/3
H3/4
H3/5
H3/6
H3/7
H3/8
H3/9
H3/10
H3/11
auxiliary output harness wiring diagram