background image

© 2001 Directed Electronics, Inc. Vista, CA

21

H3/8 GREEN (-) FACTORY SECURITY DISARM

This wire will output a (-) 200 mA pulse whenever the system is disarmed. This output can also be programmed

to provide a (-) pulse when Channel 2 is activated (see 

Systems Feature Learn Routine

section of this guide). This

makes integration of this system into a vehicle with a factory alarm very simple.

H3/9 ORANGE/BLACK (+) GHOST SWITCH INPUT

To enhance security, a secondary disarm input called the Ghost Switch is provided. The unit can be programmed

to accept a certain number of pulses (from 1 to 5) on this wire, and treat this signal as a disarm command. It

works for emergency override, VRS, and Automatic Engine Disable. The wire should be connected to a wire, prefer-

ably selected by the customer, that shows (-) ground at rest when not used and (+)12V when the switch

controlling it is operated. For example, the power window, headlight, or brake wire.

H3/10 BLACK/WHITE (-) IGNITION LOCK SAFETY INPUT

As long as this wire is grounded, the ignition controlled lock feature will be prevented. As soon as the ground is

removed, with the ignition on, the doors will lock. This can be tied to the neutral safety switch, reverse indica-

tor or brake switch wire. If this wire is not connected, the ignition controlled door lock feature will work normally.

H3/11 PINK/BLACK (-) DELAYED ACCESSORY OUTPUT

This wire provides a (-) 200 mA latched output 3 seconds after the ignition is turned on. It will remain active when

the key is turned off, until a door is opened and closed. This can be used in conjunction with a relay to energize

certain circuits in the vehicle that would normally require the key to be turned on, i.e. the radio, power windows, etc.

plug-in harnesses

The super bright LED operates at 2VDC. It plugs into the white port on the side of the unit. Make sure the LED wires

are not shorted to ground as the LED will be damaged. Multiple LED’s can be used, but they must be wired in

series. The LED fits into a 

9

/

32

-inch mounting hole. Be sure to check for clearance prior to drilling the mounting hole.

The Valet/program switch should be accessible from the driver’s seat. It plugs into the blue port on the side of

the unit. Since the system features Remote Valet, day-to-day access to the Valet/program switch is not as impor-

tant, so the switch can be hidden in a location that may not be easily accessible. If using the Ghost Switch only

disarm mode, the switch will only function to put the unit in Valet Mode and to program the unit. Consider how

the switch will be used before choosing a mounting location. Check for rear clearance before drilling a 

9

/

32

-inch

hole and mounting the switch.

valet/program switch, 2-pin plug

super-bright LED, 2-pin plug

Содержание Python 3000 ESP

Страница 1: ...2001 Directed Electronics Inc Vista CA N381 5 01 Rev M 1 0 3000 ESP Installation Guide...

Страница 2: ...s Wiring Guide 18 Driver s Door Priority Unlock Diagrams 20 Plug In Harnesses 21 Super Bright LED 2 Pin Plug 21 Valet Program Switch 2 Pin Plug 21 Shock Sensor 4 Pin Plug 22 Programmer Interface 3 Pin...

Страница 3: ...e orange wire is pre wired to control the P N 8618 starter kill relay It can supply up to 500 mA of current NOTE If connecting the orange wire to control another module such as a P N 529T or P N 530T...

Страница 4: ...ng Jumpers section of this guide this wire supplies a 200 mA output This is suitable for driving light control wires in vehicles such as Toyota Lexus BMW some Mitsubishi some Mazda and other model car...

Страница 5: ...ermined by the connection of the input wire H2 B in the Door Lock Harness NOTE If the input wire H2 B is not connected there will be no output on this wire H1 5 GREEN DOOR TRIGGER INPUT ZONE 3 Most ve...

Страница 6: ...this wire to bare metal preferably with a factory bolt rather than your own screw Screws tend to either strip or loosen with time We recommend grounding all your components including the siren to the...

Страница 7: ...12 inches of the point you obtain 12V Do not use the 15 amp fuse in the harness for this purpose This fuse protects the module itself H1 12 RED WHITE HIGH CURRENT OUTPUT FROM ON BOARD CHANNEL 2 RELAY...

Страница 8: ...doorpin circuit is positive connect to a fused 12V source H2 C H2 D H2 E H2 F H2 G AND H2 H POWER DOOR LOCK WIRES This security system has door lock relays on board the control module and can directl...

Страница 9: ...e TYPE C DIRECTLY WIRED REVERSING POLARITY SWITCHES The switches are wired directly to the motors This type of system has no factory relays Most Fords many GM two doors cars and trucks many Chryslers...

Страница 10: ...relays Many BMW s and VW s have no external switch The switches are inside the actuator and instead of pulsing the proper wires will switch back and forth from 12V to ground as the door locks are oper...

Страница 11: ...ctly to the slave switch and through to the motors These outputs rest at ground The lock or unlock wire is switched to 12V while the other wire is still grounded thus completing the circuit and poweri...

Страница 12: ...ype of door lock system there may be additional H2 harness wires that are not used for wiring the door locks H2 C WHITE BLACK Once both door lock wires are located and cut connect the white black wire...

Страница 13: ...he master switch is in the middle position H2 G BLUE BLACK Connect the blue black wire to the other side of the unlock wire Vehicles without factory power door locks require the installation of one ac...

Страница 14: ...are locked NOTE The system must be programmed for 3 5 sec door lock pulses IMPORTANT The H2 A and H2 B wires are not required for wiring the door locks For detailed wiring instructions for these two...

Страница 15: ...inning of the Door Lock Harness H2 Wire Connection Guide section Depending on the type of door lock system there may be additional H2 harness wires that are not used for wiring the door locks This sys...

Страница 16: ...ignition switch power wire or the terminal of the battery 3 Operate the door lock switch key cylinder in both directions to determine the resistor values If the multi meter displays zero resistance in...

Страница 17: ...ing 1 Cut the output wire from the door lock switch key cylinder in half 2 Test with the meter from the switch side of the cut door lock switch key cylinder wire to a reliable ground source Some good...

Страница 18: ...r 5 seconds During the 5 second recovery period an input from any sensor will reset the 5 second recovery timer This wire can be used to bypass sensors for remote starting window roll up etc PROGRAMMA...

Страница 19: ...WN HORN HONK OUTPUT This wire provides a 200mA output to drive a low current factory horn circuit The output can be programmed for a constant or pulsed output to honk the horn during the full trigger...

Страница 20: ...20 2001 Directed Electronics Inc Vista CA DRIVER S DOOR UNLOCK ONLY TYPE A DRIVER S DOOR UNLOCK ONLY TYPE B driver s door priority unlock diagrams...

Страница 21: ...ion controlled door lock feature will work normally H3 11 PINK BLACK DELAYED ACCESSORY OUTPUT This wire provides a 200 mA latched output 3 seconds after the ignition is turned on It will remain active...

Страница 22: ...ort is provided for programming of the unit When using the optional DEI Bitwriter P N 998T or PC Interface module P N 996T it is possible to configure any and all of the programmable functions The 996...

Страница 23: ...determine the light flash output In the position the on board relay is enabled and the unit will output 12V on the H1 2 WHITE wire In the position the on board relay is disabled The H1 2 WHITE wire wi...

Страница 24: ...ENTER THE SYSTEM FEATURES LEARN ROUTINE 1 Open a door The H1 5 GREEN wire or the H1 7 VIOLET wire must already be connected 2 Turn the ignition on and then back off The YELLOW wire H1 9 must already b...

Страница 25: ...nd release the Valet program switch four times Then press it once more and HOLD it The siren would chirp seven times to confirm access to the seventh feature TO SELECT ANOTHER MENU Press and HOLD the...

Страница 26: ...tion controlled domelight off 2 8 Ignition lock off if door open Ignition lock on if door open 2 9 Panic mode on Panic mode off 2 10 Door sensor bypass chirp on Door sensor bypass chirp off Feature Me...

Страница 27: ...e controls the chirps or voice messages if using the 516M that confirm the arming and disarming of the system feature menu 1 basic features FEATURE DEFAULT ONE CHIRP SETTINGS TWO CHIRP SETTINGS NUMBER...

Страница 28: ...e the vacuum pump Programming the system to provide 3 5 second pulses will accommodate the door lock interface in these vehicles The default setting is 0 8 second door lock pulses Some modification to...

Страница 29: ...tes have laws regulating how long a security system can sound When using the TechSoft Programmer or Bitwriter the siren can be programmed to sound for any length of time from 1 to 180 seconds Use the...

Страница 30: ...ion input H2 B and the output H1 4 wires must be connected as described in the Harness Wiring Guides 2 8 IGNITION LOCK WITH DOOR OPEN OFF ON If a door is open when the ignition is turned on this featu...

Страница 31: ...nlock the doors of the vehicle Pressing the disarm button again within 15 seconds of disarming will generate a pulse on the BLUE wire If programmed for second unlock the wire will also output a pulse...

Страница 32: ...2 Turn the ignition on The YELLOW wire H1 9 must be connected 3 Select the receiver channel Press and release the Valet program switch the number of times necessary to access the desired channel Pres...

Страница 33: ...eparate arm disarm and panic channels and a button from that remote is entered into Channel 1 the remote will be erased from memory and the system will only recognize the button that was entered into...

Страница 34: ...parate buttons When programmed for Expanded Configuration the transmitter buttons are assigned to the following functions The Expanded Configuration also allows the user to utilize Multi Level Securit...

Страница 35: ...n five seconds The siren chirps three times followed by a long chirp Zones Four and Six are now bypassed Pressing Button I a fourth time within five seconds The siren chirps four times followed by a l...

Страница 36: ...e of Zones to determine which input has triggered the system It is also helpful in deciding which input to use when connecting optional sensors and switches NOTE The Warn Away triggers report to the L...

Страница 37: ...Valet program switch within 5 seconds The LED will flash in groups for one minute or until the ignition is turned off to indicate the last two zones that triggered the unit NOTE The Warn Away triggers...

Страница 38: ...mes to disarm the VRS This step must be performed within 10 seconds of turning the ignition switch on NOTE When the VRS is used it is highly recommended to program the unit for Ghost Switch only disar...

Страница 39: ...ger so even if the door is instantly closed the progression from chirps to constant siren will continue Closing the door triggers the system but opening the door does not Have you correctly identified...

Страница 40: ...40 2001 Directed Electronics Inc Vista CA...

Отзывы: