The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely con
fi
dential. Any disclosure, copying, distribution to third
party is strictly prohibited.
51
387
Enable LogIn/LogOut commands?
- The ques ons Q.387 and Q.389 are very much related to each other. They deal with command execu on in
rela on with th status of being logged-in or logged-out. Their rela onship is as follows:
No / Yes
Q.387
Logged-In
Q.389
cmd=LogIn
Ac on
No
X
X
-
Normal opera on without limits.
Yes
No
No
-
Execute command without answer.
Yes
No
Yes
No
Abort Command.
Yes
No
Yes
Yes
Change status to Logged-in.
Yes
Yes
X
-
Normal opera on without limits.
The varies items in the tabel have the following meaning:
Logged-In
: is the status Logged-In? If No then the status is Logged-Out.
cmd=LogIn - is the command a Log-In command?
X
: This can be either Yes or No; it has no importance.
- : this means that it doesn’t apply.
The allowed answer is either: 0 (No: Enabled) or: 1 (Yes: Disabled).
Q 388 / Available for any possible so ware extension /
389
During LogOut mode reject commands?
- The ques ons Q.387 and Q.389 are very much related to each other.
They deal with command execu on in rela on with the status of being logged-in or logged-out. Their rela onship is as follows:
No / Yes
Q.387
Logged-In
Q.389
cmd=LogIn
Ac on
No
X
X
-
Normal opera on without limits.
Yes
No
No
-
Execute command without answer.
Yes
No
Yes
No
Abort Command.
Yes
No
Yes
Yes
Change status to Logged-in.
Yes
Yes
X
-
Normal opera on without limits.
The varies items in the tabel have the following meaning:
Logged-In : is the status
Logged-In ?
if No then the status is
Logged-Out.
cmd=LogIn : is the
command a Log-In
command ?
X : this can be either
Yes or No; it has no
importance.
- : this means that it
doesn’t apply.
The allowed answer is either: 0 (No: abort command) or: 1 (Yes: execute command (login only).
390
Enable Credit Card authoriza on numeric
fi
eld?
No / Yes
391
Baudrate for COM 1
: what is the baudrate (transmission-speed) of COM 1? The baudrate is given in baud with an accuracy of 1 baud.
The allowed value goes from 0 (min) to 65535 (max).
0 - 65535
baud
392
Maximum packet length for COM 1
: what is the maximum length of a data-packet of COM 1? The packet length is given in byte with an accuracy
of 1 byte. The allowed value goes from 1 (min) to 512 (max).
0 - 512
393
Baudrate for COM 2
: what is the baudrate (transmission-speed) of COM 2? The baudrate is given in baud with an accuracy of 1 baud.
The allowed value goes from 0 (min) to 65535 (max).
0 - 65535
baud
394
Maximum packet length for COM 2
: what is the maximum length of a data-packet of COM 2? The packet length is given in byte with an accuracy
of 1 byte. The allowed value goes from 1 (min) to 512 (max).
1 - 512
395
First cost threshold for authoriza on
: this is the
fi
rst amount above which authoriza on is requested for acceptance of the payment of the
fare with a credit-card. The cost is given in the local currency with an accuracy of 1. The allowed value goes from 0 (min) to 1000000 (max).
1 -
1000000
396
Second cost threshold for authoriza on
: this is the second amount above which authoriza on is requested for acceptance of the payment of
the fare with a credit-card. The cost is given in the local currency with an accuracy of 1. The allowed value goes from 0 (min) to 1000000 (max).
0 -
1000000
397
Third cost threshold for authoriza on
: this is the third amount above which authoriza on is requested for acceptance of the payment of the
fare with a credit-card. The cost is given in the local currency with an accuracy of 1. The allowed value goes from 0 (min) to 1000000 (max).
0 -
1000000
398
Time-out for authoriza on of payment
: this is the wai ng- me during which authoriza on is requested for acceptance of the payment of the
fare with a credit-card. If the authoriza on is not obtained within this me then the request is considered denied. The wai ng- me is given in
seconds with an accuracy of 0.1 second. The allowed value goes from 0.0 (min) to 6553.5 (max). The digit indica ng mul ples of 0.1 sec. (so at
the right of the decimal point) will
fl
ash.
0 - 65535
seconds