The Tari
ff
General Descrip on
Here follows an example of an easy tari
ff
that uses two Blocks to calculate two di
ff
erent tari
ff
amounts.
In the subscribed example there are two tari
ff
s that di
ff
er for the ini al drop value distance (
Parameter n. 11
).
The Block 1 has been programmed with an Ini al Drop Value distance of 1000, the Block 2 with a value distance of 2000.
To pass from Block 1 to Block 2 must be pressed
K1
bu on. To do it program the Parameter n. 13 of the Block n. 1 with a
value of 2 (se ng value of 2 means > go to Block 2 ).
To go back to Block 1, set in Parameter n. 13 of Block 2 the value of 1.
With this procedure it is possible to move from Block 1 to Block 2 and change the bander value by pressing
K1
bu on.
- Power on the taximeter. By default all the parameters programmed in Block 0 get loaded in the Working Block.
- Press
OP
bu on to pass in
Hired
posi on. Now
Block 1
gets loaded in the Working Block upda ng the changed param-
eters values (Parameter 11 = 0 > 11).
PS: The parameter 15 de
fi
ne the start fare block. This is the block loaded when
OP
bu on is pressed to pass from For Hire
to Hired posi on.
Working
Block
Param.001
.
.
.
.
.
Param.429
Working
Block
Param.001
.
.
P.340
.
Param.429
Working
Block
Param.001
.
.
.
.
Param.429
Working
Block
Param.001
.
P.340*
.
Param.429
Block 0
Param.001
.
.
.
.
Param.429
Easy
Tari
ff
Amount
Power
On
Power
On
Power
On
Final
Tari
ff
Amount
Complex
Tari
ff
Amount
*= Modi
fi
ed Parameter
Block 0
P.001.
.
.
.
P.015=1
.
.
.
Param.429
Wk.Block
P.001.
.
.
.
P.015=1
.
.
.
Param.429
Block 1
P.001.
.
P.011=1000
.
P.013=2
.
.
.
Param.429
Wk.Block
P.001.
.
P.011=1000
.
P.013=2
.
.
.
Param.429
Block 2
P.001.
.
P.011=2000
.
P.013=2
.
.
.
Param.429
Wk.Block
P.001.
.
P.011=2000
.
P.013=2
.
.
.
Param.429
The taximeter calculates the tari
ff
thanks to the interac on of 429 programmable parameters.
They work into a block. The M1 MDT have 63 parameters blocks that can be programmed to generate even the most
complex tari
ff
. Two blocks are very par cular: Block 0 and the Working
Block.
The
Block 0
is the StartUp block that loads per default all the 429 pa-
rameters in the Working Block when the taximeter starts up. In
a simple tari
ff
calcula on is su
ffi
cient to use only the Block 0 to
calculate the amount.
The “
Working Block
” (not visible by the user) is the
opera ve
block
that makes the
fi
nal tari
ff
calcula on.
In a simple tari
ff
, it is ge ng charged by Block 0 with his 429
default programmed parameters. It calculates the
fi
nal amount.
To calculate a more complex tari
ff
it is necessary
to use, in addi on to Block 0 , other programmed
blocks of parameters.
Their content replace, at the programmed event
(Prog.Date, Key press OP, K1, K2 etc.),
the relevant parameters of the Working Block.
Every new modi
fi
ed parameter value in a Block
will replace the old one in the Working Block up-
da ng the tari
ff
.
Example
For Hire
Hired
Hired
Содержание M1 mdt
Страница 1: ...Technical Manual InstallationandProgramming ver 1 16 12 2014...
Страница 2: ......
Страница 83: ......