The following example shows an I/O RBD error frame.
>>> z
Connecting to target...Press Ctrl/P to end connection
I
IO1> group: 0 test: 4 subtest:1
======================================================================
-----------------------
DIAGNOSTIC TEST ERROR
----------------------
GROUP: 00
Test: 04
Sub: 01
Error: 03
Pass: 00000001
Addr: 00000000
Exp: 00000000
Rec: 000000ff
Xor: 000000ff
Data Miscompare
=======================================================================
The example shows that the Module I2C EEPROM Integrity Test was executed
and failed. The XOR data specifies a data miscompare.
3–36 System Maintenance