Table 4–22 (Cont.) VAXELN Detected Error Block Entry Descriptions
Entry
Contents
7D2C
No virtual address space available
7D34
Power recovery signal
7D3C
Quit signal
7D44
Remote port value
7D4C
Process exit signal
7D54
Remote system currently unreachable
7D5C
Interprocess signal
7D64
Remote system rejected username or password
7D6C
Bad message size
7D74
Referenced shareable image not present
7D7C
Unsupported program image format
7D84
Internal consistency failure
7D8C
Port on another BI node
7D94
Third party disconnected circuit
7D9C
Network is in the off state
7DA4
No such job
7F01
Time has not been previously set
7F09
Expedited message
7F11
Previous job created area
7F19
Device already exists
ERROR_DATA
Error condition specific data. This entry is reserved for future
expansion.
4.4.5.5 Software Detected Errors
This data is provided for errors detected by the OpenVMS operating system
components. Such errors are not usually detected by hardware mechanisms. The
data is composed of information passed by the operating system component to the
EHS.
Figure 4–11 shows the format of this fault data block and the offset of each entry
from the start of the block. Table 4–23 contains a brief description of each entry.
Note
If the software component which detects the module failure does not
request the setting of the module ID NVRAM status code or does not
request a reset of the module, then these fields will contain -1 (FFFFFFFF
hexidecimal).
4–34 Error Handling and Analysis