![Digital Equipment VAXft Systems 810 Скачать руководство пользователя страница 130](http://html1.mh-extra.com/html/digital-equipment/vaxft-systems-810/vaxft-systems-810_service-information_2498646130.webp)
FTSS$_POWERGONE, Power gone fault detected on zone [zone_id]
Facility: FTSS
Explanation: Power has been lost in one of the zones. This error is
compared to its error rate threshold. If the threshold is not exceeded, the
zone will be automatically resynchronized when power returns.
User Action: If power is restored and the zone is automatically
resynchronized, no action is required on the part of the user. If power is
restored and the zone is not automatically resynchronized, the user should
examine the external system power source.
FTSS$_RESYNCHFLT, Resynch abort fault detected on [module_type] in slot
[slot_id], zone [zone_id]
Facility: FTSS
Explanation: During an attempt to resynchronize a CPU/Memory module,
an error occurred on the master CPU module. This error is compared to
its error rate threshold by the operating system. If the threshold is not
exceeded, FTSS will retry the resynchronization process. When the threshold
is exceeded, attempts to resynchronize will be terminated.
User Action: If the resynchronization retry is successful, no action is
required on the part of the user. If the threshold for retries is exceeded, the
system error log should be examined for entries which correspond to the
resynch abort failure. These entries will indicate an FRU.
FTSS$_SBE_END, SBE end action complete
Facility: FTSS
Explanation: Error processing for a single-bit memory error has been
completed and the CPU is available to be resynchronized.
User Action: If the CPU is automatically resynchronized by FTSS, then no
action is needed on the part of the user. If the CPU is not resynchronized, the
system error log should be examined for entries which correspond to single
bit error. These error logs will identify an FRU.
FTSS$_SBE_ENDTMO, SBE end action timed out on zone [zone_id]
Facility: FTSS
Explanation: When single-bit memory errors occur in a Duplex system,
diagnostics run on the failed CPU and, on completion, report status back
to the zone running the operating system. If this end action does not occur
within a reasonable timeout period, the failure will be treated as solid and
the CPU will not be automatically resynchronized by FTSS.
User Action: The system error log should be examined for entries which
correspond to the single-bit error and the end action timeout. These entries
will indicate an FRU.
FTSS$_SOLIDIOMOD, Solid I/O fault detected on [module_type] in slot [slot_id],
zone [zone_id]
Facility: FTSS
Explanation: A fatal I/O miscompare error was detected and attributed to
the indicated module. The module is removed from service by the operating
system.
User Action: The system error log should be examined for entries which
correspond to the I/O miscompare errors. These entries will indicate an FRU.
4–46 Error Handling and Analysis