Table 3–19 SF35 Operator Control Panel Description
Control/Indicator
Function
Ready
Push-to-set switch with green indicator. Brings the integrated storage
element (ISE) on-line in about 10 seconds. The indicator remains on
while the ISE is on-line.
Write Protect
Push-to-set switch with amber indicator. Write protects the data on
the ISE. The data cannot be overwritten, nor can new data be written
to the ISE.
Fault
Recessed switch with multi-color indicator. Controls the MSCP.
This switch is equivalent to the SU switch. The colors indicate the
following conditions:
Green (in) = MSCP is disabled.
Green (out)= MSCP is enabled.
Amber = Fault is detected while the MSCP is disabled.
Red = ISE fault.
Off = Normal MSCP operation.
Drive DC Power
Switches
One switch/indicator for each ISE. Apply power to the ISEs. Each
ISE spins up and runs a self-test. The indicator shows that nominal
power is being applied to the ISE. (If you want to bring the ISE
on-line, you press the Ready switch next.)
3–22 System Maintenance