Figure 4–9 shows the format of this Fault Data block entry and its offset.
Table 4–21 contains a brief description of the entry.
Figure 4–9 End Action Timeout Block
TIMEOUT_INT (Timeout Interval)
0
MR−0013−93RAGS
Table 4–21 End Action Timeout Block Entry Description
Entry
Content
Offset
TIMEOUT
End action timeout interval in seconds
0
4.4.5.4 VAXELN Detected Errors
This data is provided for errors detected by VAXELN software running on the I/O
expansion module. It is composed of data provided by VAXELN software when
the error was detected on the I/O expansion module.
Figure 4–10 shows the format of this Fault Data block and the offset of each
entry from the start of the block. Table 4–22 contains a brief description of each
entry.
Figure 4–10 VAXELN Detected Error Block
ERROR_CLASS (VAXELN Error Class)
0
+4
+8
+12
+16
MR−0014−93RAGS
ERROR_TYPE (VAXELN Error Type)
JOB_ID (ELN Component Job with Error)
ERROR_CODE (Unique Error Designation Code)
ERROR_DATA (Error Condition Specific Data)
Table 4–22 VAXELN Detected Error Block Entry Descriptions
Entry
Contents
ERROR_CLASS
VAXELN error class:
1 - VAXELN kernel fatal error
2 - VAXELN kernel recoverable error
3 - VAXELN master job fatal error
4 - VAXELN master job recoverable error
(continued on next page)
4–30 Error Handling and Analysis