V A X / V M S
SYSTEM ERROR REPORT
COMPILED
3-FEB-1993 09:33:46
PAGE
58.
BIU CTL
DFE0DEF9
Generate/Expect ECC on check_h pins
output enable of cache rams
direct mapped
2X CPU Cycle
IO Map = 1(X)
512 Kbytes
BC TAG
07913800
tag_match
tag control V
tag control D
tag P
BC TAG = 03C8(X)
BIU STAT
500E3070
Bits 33,32 BIU Addr Reg = 1(X)
Bits 33,32 Fill Addr Reg = 1(X)
FILL SYN
00000000
L0 ECC Syn bits Low Longword = 0(X)
Hi ECC Syn bits High Longword = 0(X)
FILL ADDR
000002A8
FILL ADDR = 000002A8(X)
VMAR
000007E0
Sub Block Select = 0(X)
Row Index = 3F(X)
Error Address Field = 00000000(X)
ICSR
00000001
enable VIC
TBADR
00000000
TBSTS
00000000
s5 cmd corresp to tb perr
= 00
source of ref causing tb perr
= 00
PCSTS
00000000
PCSTS.LOCK(0) NOT SET
PCCTL
00000000
Performance Monitor Mode = 0(X)
COMPAT/STAT REG 00006008
ATM self test failed
ATM ID EEPROM is bad
ATM ID EEPROM has bad os status
DIAG STATUS REG 00000000
Register is not "VALID"
!
This block reflects the content of the four fields of the Fault Summary Block.
"
This entry type (end action) is provided after diagnostics have completed
running on a zone or CPU which has been removed from service as a result of
a system error.
This is the end action for the previous example (CPU/MEM Fault Error Log
Entry).
#
This message specifies that a physical FRU replacement is required.
$
The system operating mode has been changed from Duplex to Degraded
Duplex with Zone A as the master.
%
The FRU may be one of five items: CPU module, or one of the four MMBs.
&
The Zone B CPU has been removed from service.
'
Double-bit errors are always treated as solid faults. The failed CPU will not
be reconfigured until Zone B memory is repaired. MMB 3 is the most likely
FRU.
Error Handling and Analysis 4–71