Table 3–18 RF35 Disk Drawer Controls and Indicators
Control/Indicator
Color
State
Operating Condition
Fault
Red
On
Drive is faulty.
Off
Drive is functioning correctly.
Write Protect
Amber
Out, off
System can read from the disk and write to
the disk.
In, on
System cannot write to the disk, but can
read from the disk.
On Line
Green
Out, off
Drive is disabled.
In, on
Drive is enabled.
Power On/Off
Green
In, on
Power is on.
Out, off
Power is off.
Set Up Switch
In
Prevents the drive from joining the DSSI
cluster. Also allows you to set the DSSI
parameters for a new drive or a drive you
replace in the system after repair. (If you
want to set the DSSI parameters, you press
the Set Up switch and the Power On/Off
switch at the same time.)
Out
Has no effect on the drive.