6–12
Table 6–1. LCD Message Troubleshooting Table
Displayed
Message
Operator
Can
Correct?
Explanation
Solution
8.5V PWR FAIL*
No
Internal power
failure.
Contact your Digital Customer
Service Engineer.
1
15V CTL FAIL*
No
Controller voltage
failure.
Contact your Digital Customer
Service Engineer.
1
23.5V CTL FAIL*
No
Controller voltage
failure.
Contact your Digital Customer
Service Engineer.
1
48V PWR FAIL*
No
Internal power
failure.
Contact your Digital Customer
Service Engineer.
1
ACCESS NULL PTR*
No
Fatal firmware error
on CMX controller
board.
Contact your Digital Customer
Service Engineer.
1
A TO D OVERUN*
No
Fatal firmware error
on CMX controller
board.
Contact your Digital Customer
Service Engineer.
1
BAD VFU CHANNEL
Yes
Error in channel
assignment for a
Vertical Format Unit
(VFU), for one of the
LinePrinter Plus
emulations.
Refer to the LinePrinter Plus
Programming Reference Manual
chapter on “Vertical Formatting”
for further information.
BUFFER OVERFLOW
Yes
Host sends data after
the printer buffer is
full. (Serial
interface.)
Check your serial host interface
parameter settings; if necessary,
adjust them so that they match
the settings of the attached host.
CLEAR PAPER JAM
Yes
No paper motion.
Clear jam and reload paper (see
Operator’s Guide). If this
message recurs, contact your
Digital Customer Service
Engineer.
1
CLOSE PLATEN
Yes
The forms thickness
lever is open.
Close the forms thickness lever
(see page 2–20.)
1
Before contacting a Digital Customer Service Engineer, power off the printer, wait 15 seconds, then
power it back on and rerun your print job. If the message reappears, press CLEAR then ONLINE. If
the fault message still displays, then contact the Customer Service Engineer.