5.2 Types of Tests
5.2.2 Test Descriptions
This section briefly describes the diagnostic and utility programs:
•
acu_bound
— ACU Boundary Test
Tests the ability of macro code to operate across page and row boundaries.
•
acu_clim
Tests the action of the ACU when certain CMEM limits and alignments are
violated.
•
acu_diag
This test suite checks the ACU PCB. The tests in the suite are listed in
Section 5.2.1.1.
•
acu_int
Tests the operation of interrupts.
•
acu_macro
Tests the ability of macro code to execute basic instructions.
•
acu_micro
Tests data paths, registers, and components on the ACU PCB.
•
acu_pgtbl
Tests the page table translation and comparison mechanism.
•
acu_pptest
Verifies the 32 general-purpose registers are functional; uses peeks and pokes.
•
acu_prof
Tests the three profile counters and the profile configuration register.
•
acu_reg1
Tests the ACU front-end registers.
•
acu_reg2
Tests the ACU front-end firmware-emulated registers.
•
acu_sup
Tests the hardware necessary to support user/supervisor mode firmware,
CMEM address map, and software interrupt generation.
5–4 Using Diagnostic Software