- 222 -
H
-
I
%(I
2
/I
1
)>
Broken conductor protection function. / Instantaneous tripping due to broken conductor
protection. / Broken conductor protection threshold value.
I<
Undercurrent protection function. / Instantaneous tripping due to undercurrent protection. /
Undercurrent protection threshold value.
I>
Phase overcurrent 1
st
threshold protection function. / Instantaneous tripping due to phase
overcurrent 1
st
threshold protection. / Phase overcurrent protection 1
st
threshold value.
I>>
Phase overcurrent 2
nd
threshold protection function. / Instantaneous tripping due to phase
overcurrent 2
nd
threshold protection. / Phase overcurrent protection 2
nd
threshold value.
I>>>
Phase overcurrent 3
rd
threshold protection function. / Instantaneous tripping due to phase
overcurrent 3
rd
threshold protection. / Phase overcurrent protection 3
rd
threshold value.
I
e
>
Earth overcurrent 1
st
threshold protection function. / Instantaneous tripping due to earth
overcurrent 1
st
threshold protection. / Earth overcurrent protection 1
st
threshold value.
I
e
>>
Earth overcurrent 2
nd
threshold protection function. / Instantaneous tripping due to earth
overcurrent 2
nd
threshold protection. / Earth overcurrent protection 2
nd
threshold value.
I
e
>>>
Earth overcurrent 3
rd
threshold protection function. / Instantaneous tripping due to earth
overcurrent 3
rd
threshold protection. / Earth overcurrent protection 3
rd
threshold value.
I
n
Nominal current.
I
r
Rated current.
I
s
Set / threshold current.
I
θ
>
Thermal overload protection.
I
2
>
Negative sequence overcurrent 1
st
threshold protection function. / Instantaneous tripping
due to negative sequence overcurrent 1
st
threshold protection. / Negative sequence
overcurrent protection 1
st
threshold value.
I
2
>>
Negative sequence overcurrent 2
nd
threshold protection function. / Instantaneous tripping
due to negative sequence overcurrent 2
nd
threshold protection. / Negative sequence
overcurrent protection 2
nd
threshold value.
IDMT
Inverse Definite Minimum Time.
IEC
International Electro-technical Commission.
IEEE
Institute of Electrical and Electronics Engineers, U.S.A.
IP
International Protection Rating according to IEC 60529 Standard.
IP20
Protection against objects with size >12.5mm.
IP52
Protection against dust and dripping water when tilted up 15°.
ISO
International Organization for Standardization.
J
-
K
-
L
L5
Programmable LED no.5.
L6
Programmable LED no.6.
L7
Programmable LED no.7.
L8
Programmable LED no.8.
L9
Programmable LED no.9.
L10
Programmable LED no.10.
L11
Programmable LED no.11.
L12
Programmable LED no.12.
Latch
Relay locking.
Содержание CPM 310 G
Страница 1: ...CPM 310 G Digital Overcurrent Protection Relay User Application Manual vEN 2016 03...
Страница 2: ...2...
Страница 6: ...6 ABOUT DEMA...
Страница 11: ...11 INTRODUCTION...
Страница 32: ...32 PACKING LABELING INFORMATION...
Страница 34: ...34 OPERATING MANUAL...
Страница 53: ...53 RELAY MENUS MANUAL...
Страница 55: ...55 The Menu Tree...
Страница 56: ...56...
Страница 57: ...57...
Страница 58: ...58...
Страница 59: ...59...
Страница 60: ...60...
Страница 61: ...61...
Страница 128: ...128 DIGICONNECT PC PROGRAM MANUAL...
Страница 189: ...189 APPLICATION DIAGRAMS...
Страница 191: ...191 Sample Power Transformer Protection Application Diagram...
Страница 193: ...193 FUNDAMENTAL CABLING DIAGRAM...
Страница 195: ...195 APPLICATION DIAGRAM NO 2 Function Function Activation Address Output Settings Internal Error Alarm Automatic...
Страница 203: ...203 APPLICATION DIAGRAM NO 10 RS485 Cabling...
Страница 204: ...204 TECHNICAL DATA...
Страница 220: ...220 GLOSSARY...