Chapter 2 Installation and Storage
2-2
Revision June 2010
2.3 Installation
Conditions
Operating Temperature
ASDA-B2 Series Servo Drive :
0°C to 55°C (32°F to 131°F)
ECMA Series Servo Motor
:
0°C to 40°C (32°F to 104°F)
The ambient temperature of servo drive should be under 45°C (113°F) for long-term
reliability.
If the ambient temperature of servo drive is greater than 45°C (113°F), please install the drive
in a well-ventilated location and do not obstruct the airflow for the cooling fan.
Caution
The servo drive and motor will generate heat. If they are installed in a control panel, please
ensure sufficient space around the units for heat dissipation.
Pay particular attention to vibration of the units and check if the vibration has impacted the
electric devices in the control panel. Please observe the following precautions when selecting
a mounting location.
Failure to observe the following precautions may void the warranty!
Do not mount the servo drive or motor adjacent to heat-radiating elements or in direct
sunlight.
Do not mount the servo drive or motor in a location subjected to corrosive gases, liquids,
airborne dust or metallic particles.
Do not mount the servo drive or motor in a location where temperatures and humidity will
exceed specification.
Do not mount the servo drive or motor in a location where vibration and shock will exceed
specification.
Do not mount the servo drive or motor in a location where it will be subjected to high
levels of electromagnetic radiation.
Содержание ASD-B2-0121-B
Страница 1: ......
Страница 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Страница 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Страница 19: ...Chapter 1 Unpacking Check and Model Explanation 1 6 Revision June 2010 1 4 Servo Drive Features...
Страница 21: ...Chapter 1 Unpacking Check and Model Explanation 1 8 Revision June 2010 This page intentionally left blank...
Страница 25: ...Chapter 2 Installation and Storage 2 4 Revision June 2010 Minimum Clearances Side by Side Installation...
Страница 43: ...Chapter 3 Connections and Wiring 3 6 Revision June 2010 Figure 3 3 Three Phase Power Supply all models...
Страница 72: ...Chapter 3 Connections and Wiring Revision June 2010 3 35 3 5 2 Connection between PC and Connector CN3...
Страница 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Страница 100: ...Chapter 5 Trial Run and Tuning Procedure Revision June 2010 5 13 5 5 2 Load Inertia Estimation Flowchart...
Страница 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Страница 153: ...Chapter 6 Control Modes of Operation 6 44 Revision June 2010 This page intentionally left blank...
Страница 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Страница 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Страница 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...