Chapter 8 MODBUS Communications
8-12
Revision June 2010
RTU Mode:
Command message:
Response message:
ADR 01H
ADR 01H
CMD 06H
CMD 06H
02H (Upper bytes)
02H (Upper bytes)
Starting data
address
00H (Lower bytes)
Starting data
address
00H (Lower bytes)
00H (Upper bytes)
00H (Upper bytes)
Content of data
64H (Lower bytes)
Content of data
64H (Lower bytes)
CRC Check Low
89H (Lower bytes)
CRC Check Low
89H (Lower bytes)
CRC Check High
99H (Upper bytes)
CRC Check High
99H (Upper bytes)
LRC (ASCII Mode):
LRC (Longitudinal Redundancy Check) is calculated by summing up, module 256, the values
of the bytes from ADR to last data character then calculating the hexadecimal representation
of the 2’s-complement negation of the sum.
For example, reading 1 word from address 0201H of the ASDA-B2 series AC servo drive with
address 01H.
STX ‘:’
‘0’
ADR
‘1’
‘0’
CMD
‘3’
‘0’
‘2’
‘0’
Starting data address
‘1’
‘0’
‘0’
‘0’
Number of data
‘1’
‘F’
LRC Check
‘8’
End 1
(0DH)(CR)
End 0
(0AH)(LF)
01H+03H+02H+01H+00H+01H = 08H, the 2’s complement negation of 08H is F8H.
Hence, we can know that LRC CHK is ’F’,’8’.
Содержание ASD-B2-0121-B
Страница 1: ......
Страница 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Страница 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Страница 19: ...Chapter 1 Unpacking Check and Model Explanation 1 6 Revision June 2010 1 4 Servo Drive Features...
Страница 21: ...Chapter 1 Unpacking Check and Model Explanation 1 8 Revision June 2010 This page intentionally left blank...
Страница 25: ...Chapter 2 Installation and Storage 2 4 Revision June 2010 Minimum Clearances Side by Side Installation...
Страница 43: ...Chapter 3 Connections and Wiring 3 6 Revision June 2010 Figure 3 3 Three Phase Power Supply all models...
Страница 72: ...Chapter 3 Connections and Wiring Revision June 2010 3 35 3 5 2 Connection between PC and Connector CN3...
Страница 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Страница 100: ...Chapter 5 Trial Run and Tuning Procedure Revision June 2010 5 13 5 5 2 Load Inertia Estimation Flowchart...
Страница 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Страница 153: ...Chapter 6 Control Modes of Operation 6 44 Revision June 2010 This page intentionally left blank...
Страница 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Страница 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Страница 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...