Geo Brick Drive User Manual
Pinouts and Software Setup
36
J3: External Shunt Resistor
J3 is used to wire an external shunt resistor to expel the excess power during demanding deceleration
profiles. The GAR10 and GAR15 resistors are designed to drain excess bus energy very quickly. The 4-
and 8-axis Geo Brick Drives are designed for operation with external shunt resistors of 15 Ohms, 6-axis
units requiring 10 Ohms. Delta Tau provides these resistors with pre-terminated cables that plug directly
into connector J3.
Caution
All applications using Geo Brick Drives (all configurations) are
strongly advised to install an external shunt resistor.
4-, And 8-Axis Geo Brick
J3: Molex 2-pin Female
Mating: Molex 2-pin Male
Regen+
Regen-
Regen+
Regen-
CAP-
GBL4
GBL6
GBL8
Pin #
Symbol
Function
1
REGEN-
Output
2
REGEN+
Output
Molex Mating Connector p/n:
0444412002
Molex Crimper tool p/n:
63811-0400
Molex Pins p/n:
0433751001
Delta Tau Mating Connector p/n: 014-000F02-HSG
Delta Tau Pins p/n:
014-043375-001
6-Axis Geo Brick
J3: Molex 3-pin Female
Mating: Molex 3-pin Male
Regen+
Regen-
Regen+
Regen-
CAP-
GBL4
GBL6
GBL8
1
CAP-
Bus – (do not wire)
2
REGEN-
Output
3
REGEN+
Output
Molex Mating Connector p/n:
0428160312
Molex Crimper tool p/n:
63811-1500
Molex Pins p/n:
0433751001
Delta Tau Mating Connector p/n: 014-H00F03-049
Delta Tau Pins p/n:
014-042815-001