Geo Brick Drive User Manual
Macro Connectivity
245
18.
Typical MACRO motor settings
The motor command output address
Ixx02
is initiated by default in the firmware
MACRO
motor
Motor #
Ixx02
Register
MACRO
motor
Motor #
Ixx02
Register
1
st
5 or 9
$078420
Servo Node 0
5
th
9 or 13
$078430
Servo Node 8
2
nd
6 or 10
$078424
Servo Node 1
6
th
10 or 14 $078434
Servo Node 9
3
rd
7 or 11
$078428
Servo Node 4
7
th
11 or 15 $078438
Servo Node 12
4
th
8 or 12
$07842C Servo Node 5
8
th
12 or 16 $07843C Servo Node 13
The flag address
Ixx25
is initiated by default in the firmware.
MACRO
motor
Motor #
Ixx25
Register
MACRO
motor
Motor #
Ixx25
Register
1
st
5 or 9
$3440
Servo Node 0
5
th
9 or 13
$3448
Servo Node 8
2
nd
6 or 10
$3441
Servo Node 1
6
th
10 or 14
$3449
Servo Node 9
3
rd
7 or 11
$3444
Servo Node 4
7
th
11 or 15
$344C
Servo Node 12
4
th
8 or 12
$3445
Servo Node 5
8
th
12 or 16
$344D
Servo Node 13
The Flag Control
Ixx24
is typically set to
$40001
($60001 to disable hardware over-travel limits).
The commutation position addresses
Ixx83
is initiated by default in the firmware.
MACRO
motor
Motor #
Ixx83
Register
MACRO
motor
Motor #
Ixx83
Register
1
st
5 or 9
$078420
Servo Node 0
5
th
9 or 13
$078430
Servo Node 8
2
nd
6 or 10
$078424
Servo Node 1
6
th
10 or 14 $078434
Servo Node 9
3
rd
7 or 11
$078428
Servo Node 4
7
th
11 or 15 $078438
Servo Node 12
4
th
8 or 12
$07842C Servo Node 5
8
th
12 or 16 $07843C Servo Node 13
The commutation enable
Ixx01
should be set to 3, indicating that commutation is performed from
Y registers (specified in Ixx83).
The PWM Scale Factor
Ixx66
is set up as follows:
If Motor Voltage > Bus Voltage:
Ixx66 = 1.1 * 16384
If Motor Voltage < Bus Voltage:
Ixx66 = 1.1 * 16384 * MtrVolt / BusVolt
The commutation angle
Ixx72
should be set to
1365
.
The current feedback mask
Ixx84
should be set to
$FFF000
.
Содержание Geo Brick
Страница 5: ...4...
Страница 286: ...Geo Brick Drive User Manual Appendix A 286 APPENDIX A Schematic Samples Watchdog X15 Inputs J6 J7...
Страница 287: ...Geo Brick Drive User Manual Appendix A 287 Outputs J6 J7 603793 109 and earlier Outputs J6 J7 603793 10A and later...
Страница 288: ...Geo Brick Drive User Manual Appendix A 288 Limits Flags J4...