Geo Brick Drive User Manual
Pinouts and Software Setup
35
Disabling the STO (Backward compatibility)
Disabling the STO maintains full backward compatibility with existing systems, pre-STO installations.
This is done by simply tying STO IN (pin #1) to +24V (pin #3):
24 VDC
Power Supply
J2
+24V
24V RET
COM
+24 VDC
STO OUT
STO IN
1
2
3
4
Wiring and Using the STO
24 VDC
Power Supply
J2
+24V
24V RET
COM
+24 VDC
STO OUT
STO IN
1
2
3
4
N.C
Input to Brick/Logic
In normal mode operation, the STO relay must be normally closed. +24V must be applied to STO
IN (pin #1) to allow power to the motors.
The STO is triggered, and power is disconnected from the motors, if the +24V is disconnected
from STO IN (pin #1).
In this mode, the Drive will display an AF2 fault on the 7-sgment display.
The STO OUT (pin #2) is a voltage status output rated to 24V
±5% at a max of 125mA. It
reflects the status of the STO function. It can be brought into a general purpose input or
to external safety logic.
(24V) in normal mode operation (+24V applied to STO IN)
(0 V) in triggered mode (+24V no applied to STO IN)
The STO relay can be wired in series with the E-Stop circuitry which typically disconnects the
main bus power from the system.
Note
If the STO fault condition has been removed (wired properly), the
AF2 fault display can be cleared with the AMPCLRF command.