![Delta Tau Geo Brick Скачать руководство пользователя страница 211](http://html1.mh-extra.com/html/delta-tau/geo-brick/geo-brick_user-manual_2478499211.webp)
Geo Brick Drive User Manual
Motor Setup
211
Motor Quadrature/Torque Command Value Registers
Motor #
Address
(X-Memory)
Motor #
Address
(X-Memory)
1
$0000BF
5
$0002BF
2
$00013F
6
$00033F
3
$0001BF
7
$0003BF
4
$00023F
8
$00043F
Motor Activation, Position, Velocity Pointers: Ixx03, Ixx04
The position and velocity pointers (no external encoder used) will be set to the integration result:
I400=1
; Motor #4 Active
I403=$350B
I404=$350B
; Motor #4 position and velocity feedback Address
Commutation Angle, Current Mask, Flag Mode Control: Ixx72, Ixx84, Ixx24
I472=1365
; Motors #4 Commutation phase angle (Geo Brick Drive specific)
I484=$FFF000
; Motors #4 Current-Loop Feedback Mask Word (Geo Brick Drive specific)
I424=$000401
; Disable 3
rd
harmonic, enable over-travel limits
PWM Scale Factor: Ixx66
If Motor Rated Voltage > Bus Voltage:
I466=1.10*I7000
; Motor #4 PWM Scale Factor. Set to 10% above PWM Count.
If Bus Voltage > Motor Rated Voltage:
A Geo Brick Drive connected to 3-Phase 230 VAC Bus, driving a 110 VAC Induction Motor. In this
case, Ixx66 serves as a voltage limit for the motor
#define BusInput
230
; Bus Voltage, 230 VAC
-User Input
#define Mtr4Voltage
110
; Motor #4 Rated Voltage, 110 VAC Motor
-User Input
I466=1.10*I7000*Mtr4Voltage/BusInput ; Motor #4 PWM Scale Factor
Current Feedback Address: Ixx82
I482=$07801E
; Motor 4 Current Feedback Address
Commutation Position Address, Commutation Enable: Ixx83, Ixx01
I483=$350B
; Motor #4 On-Going Commutation Position Address (from Integration Result)
I401=1
; Motor #4 Commutation Enabled, from X-register
Commutation Cycle size: Ixx70, Ixx71
I470=1
; Direct-Microstepping technique specific
I471=65536
; Direct-Microstepping technique specific