![Delta Tau Geo Brick Скачать руководство пользователя страница 265](http://html1.mh-extra.com/html/delta-tau/geo-brick/geo-brick_user-manual_2478499265.webp)
Geo Brick Drive User Manual
Drive Structure and Troubleshooting
265
Error Codes
The Global and Axis faults are interpreted by the Amplifier processor(s) and sent to the 7-
segment 3-character scrolling display (D1 amp status).
The scrolling display begins with a number indicating the faulted axis number (
1
-
8
) or the letter
A
indicating a Global Fault, followed by the letter
F
indicating a fault, followed by the specific Fault Code.
The blinking dot is the heartbeat of the drive processor(s) and is always active in normal mode operation.
It is turned off or not blinking when the drive is in reset mode (reloading firmware) or has no logic power.
The display is blank if there are no axes enabled, and no faults.
Axis Faults (n = 1 - 8)
Display
Bit
Code
Description
nF1
$01
Axis-n Peak Current Fault:
Indicates that a current output greater than the amplifier
peak current specification (but less than the short circuit nF3 threshold) has been
detected and sustained for about 10 milliseconds.
nF2
$02
Axis-n RMS Current Fault:
Indicates that the amplifier I2T model, hard-coded in the
amplifier processor projecting current output over time, has been violated within the
operating current specification range of the amplifier. Over-sized motor?
nF3
$03
Axis-n Short Circuit Fault:
Indicates that the short circuit current output threshold
(twice the rated peak current) has been exceeded (fast acting very high current output)
and sustained for about 10 microseconds. Check motor wiring for shorts. Unplug motor
cable and recycle power (strongly advised).
nF5
$05
Power Stage (IGBT) Over-Temperature Fault:
Indicates excessive IGBT
temperature (or below operating temperature of 0 Celsius) has been detected.
0
$FF
Axis-n Enabled:
Normal mode operation, one or more axes enabled.
Содержание Geo Brick
Страница 5: ...4...
Страница 286: ...Geo Brick Drive User Manual Appendix A 286 APPENDIX A Schematic Samples Watchdog X15 Inputs J6 J7...
Страница 287: ...Geo Brick Drive User Manual Appendix A 287 Outputs J6 J7 603793 109 and earlier Outputs J6 J7 603793 10A and later...
Страница 288: ...Geo Brick Drive User Manual Appendix A 288 Limits Flags J4...