Geo Brick Drive User Manual
Motor Setup
167
AC/DC Brushless (Rotary/Linear) Motor Setup
Before you start
At this point of the setup process it is assumed that the encoder has been wired and configured
correctly in the Encoder Feedback section. And that moving the motor/encoder shaft by hand
shows encoder counts in the position window.
Parameters with comments ending with
-User Input
require the user to enter information
pertaining to their system/hardware.
Downloading and using the suggested M-variables is highly recommended.
Description of the setup parameters can be found in the
Turbo Software Reference Manual
Commutation Angle, Current Mask: Ixx72, Ixx84
I172,8,100=1365
; Motors 1-8 Commutation phase angle (Geo Brick Drive specific)
I184,8,100=$FFF000
; Motors 1-8 Current-Loop Feedback Mask Word (Geo Brick Drive specific)
PWM Scale Factor: Ixx66
If Motor Rated Voltage > Bus Voltage:
I166=1.10*I7000
; Motor #1 PWM Scale Factor. Set to 10% above PWM Count.
I266=I166 I366=I166 I466=I166 I566=I166
; Assuming same motor(s) as motor #1
I666=I166 I766=I166 I866=I166
; Assuming same motor(s) as motor #1
If Bus Voltage > Motor Rated Voltage:
Ixx66 acts as a voltage limiter. In order to obtain full voltage output it is set to about 10% over PWM
count divided by DC Bus/Motor voltage ratio. For example:
#define DCBusInput
325
; DC Bus Voltage [VDC] = 1.414* 230 VAC
-User Input
#define Mtr1Voltage
156
; Motor 1 Rated Voltage [VDC], 110 VAC Motor
-User Input
#define Mtr2Voltage
156
; Motor 2 Rated Voltage [VDC], 110 VAC Motor
-User Input
#define Mtr3Voltage
156
; Motor 3 Rated Voltage [VDC], 110 VAC Motor
-User Input
#define Mtr4Voltage
156
; Motor 4 Rated Voltage [VDC], 110 VAC Motor
-User Input
#define Mtr5Voltage
156
; Motor 5 Rated Voltage [VDC], 110 VAC Motor
-User Input
#define Mtr6Voltage
156
; Motor 6 Rated Voltage [VDC], 110 VAC Motor
-User Input
#define Mtr7Voltage
156
; Motor 7 Rated Voltage [VDC], 110 VAC Motor
-User Input
#define Mtr8Voltage
156
; Motor 8 Rated Voltage [VDC], 110 VAC Motor
-User Input
I166=1.10*I7000*Mtr1Voltage/DCBusInput
; Motor 1 PWM Scale Factor
I266=1.10*I7000*Mtr2Voltage/DCBusInput
; Motor 2 PWM Scale Factor
I366=1.10*I7000*Mtr3Voltage/DCBusInput
; Motor 3 PWM Scale Factor
I466=1.10*I7000*Mtr4Voltage/DCBusInput
; Motor 4 PWM Scale Factor
I566=1.10*I7000*Mtr5Voltage/DCBusInput
; Motor 5 PWM Scale Factor
I666=1.10*I7000*Mtr6Voltage/DCBusInput
; Motor 6 PWM Scale Factor
I766=1.10*I7000*Mtr7Voltage/DCBusInput
; Motor 7 PWM Scale Factor
I866=1.10*I7000*Mtr8Voltage/DCBusInput
; Motor 8 PWM Scale Factor
Current Feedback Address: Ixx82
I182=$078006
; Motor 1 Current Feedback Address
I282=$07800E
; Motor 2 Current Feedback Address
I382=$078016
; Motor 3 Current Feedback Address
I482=$07801E
; Motor 4 Current Feedback Address
I582=$078106
; Motor 5 Current Feedback Address
I682=$07810E
; Motor 6 Current Feedback Address
I782=$078116
; Motor 7 Current Feedback Address
I882=$07811E
; Motor 8 Current Feedback Address