Resolver
With resolvers, it is recommended to use the unfiltered data processed in the Encoder Conversion Table:
// these addresses can differ depending on the encoder conversion table management
I183=$3503
; Motor 1 On-going Commutation Position Address
I283=$350B
; Motor 2 On-going Commutation Position Address
I383=$3513
; Motor 3 On-going Commutation Position Address
I483=$351B
; Motor 4 On-going Commutation Position Address
I583=$3523
; Motor 5 On-going Commutation Position Address
I683=$352B
; Motor 6 On-going Commutation Position Address
I783=$3533
; Motor 7 On-going Commutation Position Address
I883=$353B
; Motor 8 On-going Commutation Position Address
I101,8,100=1
; Motors 1-8 Commutation Enabled, from X-register
Yaskawa
With Yaskawa feedback devices, it is recommended to use the processed data in the Encoder Conversion
Table (same as position):
I183=I104
; Motor 1 On-going Commutation Position Address
I283=I204
; Motor 2 On-going Commutation Position Address
I383=I304
; Motor 3 On-going Commutation Position Address
I483=I404
; Motor 4 On-going Commutation Position Address
I583=I504
; Motor 5 On-going Commutation Position Address
I683=I604
; Motor 6 On-going Commutation Position Address
I783=I704
; Motor 7 On-going Commutation Position Address
I883=I804
; Motor 8 On-going Commutation Position Address
I101,8,100=1
; Motors 1-8 Commutation Enabled, from X-register