![Delta Tau Geo Brick Скачать руководство пользователя страница 280](http://html1.mh-extra.com/html/delta-tau/geo-brick/geo-brick_user-manual_2478499280.webp)
Geo Brick Drive User Manual
Drive Structure and Troubleshooting
280
Reloading Boot and Communication Firmware
The boot and firmware .IIC files are required for this procedure. They are normally obtained directly from
Delta Tau, or downloaded from the PMAC forum Webpage. The following steps ensure proper
configuration:
Caution
Downloading the wrong boot or communication files will severely
corrupt the functionality of the communication processor.
Step1:
Hold the BOOT SW switch down
Step2:
Click on Store Boot
Step3:
The utility will prompt for the boot file. MAKE SURE you open the correct .IIC file (ending with
BootFx2.iic) and wait for “firmware load successful” message
Step4:
Click on Store F/W
Note
The BOOT SW switch button can be released temporarily (between
file downloads). But it MUST to be held down the entire time the boot
or firmware files are being written.
Step5:
The utility will prompt for the Firmware file. MAKE SURE you open the correct .IIC file (ending
with ETHUSB307FX2.iic) and wait for “firmware load successful” message
Step6:
Release the BOOT SW switch. Click Done, and recycle logic power (24V) on the Brick.