Geo Brick Drive User Manual
Drive Structure and Troubleshooting
266
Global Faults
Display
Bit
Code
Description
AF1
$04
PWM Over Frequency Fault:
Indicates that the PWM has exceeded the specified
limit. This can occur if clock settings are incorrect, or in some cases if main bus power
is not applied.
AF2
Safe Torque Off, STO Fault:
The +24V is not applied to STO IN (J2 pin #1).
No power output to the motors is allowed in this mode.
AF3
$0D
EEPROM Communication Fault:
Indicates that the memory has been corrupted.
AF4
$0E
Shunt RMS Fault:
Indicates that the shunt resistor turn-on time has exceeded the
permissible time of 2 seconds. Make sure that the main bus power is within spec.
AFb
$07
Main Bus Over Voltage Fault:
Indicates that either excessive bus voltage has been
detected, or bus voltage is not present. Make sure a shunt resistor is installed.
AFd
$09
Shunt resistor Short Circuit Fault:
Indicates that a short has been detected at the
Shunt resistor circuitry.
AFL
$0C
Main Bus Input Voltage Fault:
Indicates that there is no main bus power or has
dropped below the minimum threshold (87 VAC).
U
EPROM Corrupted
Note
Once the fault condition has been removed, the fault display can be
cleared with the AMPCLRF command.
Содержание Geo Brick
Страница 5: ...4...
Страница 286: ...Geo Brick Drive User Manual Appendix A 286 APPENDIX A Schematic Samples Watchdog X15 Inputs J6 J7...
Страница 287: ...Geo Brick Drive User Manual Appendix A 287 Outputs J6 J7 603793 109 and earlier Outputs J6 J7 603793 10A and later...
Страница 288: ...Geo Brick Drive User Manual Appendix A 288 Limits Flags J4...