![Delta Tau Geo Brick Скачать руководство пользователя страница 247](http://html1.mh-extra.com/html/delta-tau/geo-brick/geo-brick_user-manual_2478499247.webp)
Geo Brick Drive User Manual
Macro Connectivity
247
20.
Motor Phasing, Open-Loop Test
Motor phasing is performed in the same manner as it would be for any digitally commutated motor.
The following is a satisfactory open loop test:
An erratic or inverted saw tooth response is typically (with quadrature, or sinusoidal encoders) an
indication of reversed encoder direction –with respect to the output command- The encoder decode
parameter
MS{node},I910
can then be changed from 7 to 3 or vice versa. Phasing has to be
performed again after this parameter has been changed.
21.
Tuning the Position-Loop
Tuning the position loop PID gains can be carried on in the traditional manner - see motor setup section in
this manual- there are no special instructions for tuning MACRO motors.
Содержание Geo Brick
Страница 5: ...4...
Страница 286: ...Geo Brick Drive User Manual Appendix A 286 APPENDIX A Schematic Samples Watchdog X15 Inputs J6 J7...
Страница 287: ...Geo Brick Drive User Manual Appendix A 287 Outputs J6 J7 603793 109 and earlier Outputs J6 J7 603793 10A and later...
Страница 288: ...Geo Brick Drive User Manual Appendix A 288 Limits Flags J4...