Error 18 (Erro18)
Error 18 “Attempt to perform phase reference during move, move during phase reference, or enabling
with phase clock error” is highlighted in red in the terminal window:
This error occurs if any of the following is true:
The addressed motor is not phased.
In this mode, the phasing search error bit is highlighted in the Motor Status window.
No Phase Clock (internal).
In this mode, the Phase Clock Missing bit is highlighted in the Global Status window.
+24V Abort not applied.
In this mode, the Abort Input bit is highlighted in the Global Status window.