![Delta Tau Geo Brick Скачать руководство пользователя страница 152](http://html1.mh-extra.com/html/delta-tau/geo-brick/geo-brick_user-manual_2478499152.webp)
Geo Brick Drive User Manual
Pinouts and Software Setup
152
X15: Watchdog and ABORT (TB2)
X15 has two essential functions:
A 24VDC Abort Input (mandatory for normal operation) which can be used in various
applications to halt motion when necessary (i.e. opening machine door, replacing tool).
A watchdog relay output allowing the user to bring the machine to a stop in a safe manner in the
occurrence of a watchdog.
X15: Phoenix 5-pin TB Female
Mating: Phoenix 5-pin TB Male
1
2
3
4
5
TB-5: 016-PL0F05-38P
Pin #
Symbol
Function
Notes
1
ABORT-
Input
ABORT Return
2
ABORT+
Input
ABORT Input 24VDC
3
WD N.O.
Output
Watchdog (normally open contact)
4
WD N.C.
Output
Watchdog (normally closed contact)
5
WD COM
Common
Watchdog common
Wiring the Abort Input
If an Abort toggle button is used, it must be a normally closed switch.
1
2
3
4
5
24VDC
Power Supply
COM
24VDC
Abort Input
Switch (optional)
The hardware Abort input functionality differs slightly from the software global Abort (CTRL-A)
command. The main differences are highlighted in the following table:
Motor(s) Status
Before Abort Action
Software Abort
(e.g. ^A)
Hardware Abort
(Removing 24VDC)
Killed
(Open-Loop mode)
Closes the position-loop on
all active (Ixx0=1) motors
No Action is taken.
Motors remain killed
Amplifier Enabled
(i.e. #1o0, Open-Loop mode)
Closes the position-loop
on all active (Ixx0=1) motors
Closes the position-loop on all
‘amplifier enabled’ motors only.
Killed motors remain killed.
Servo-ing – in position
(Closed-Loop mode)
Motor(s) remain in
closed-loop at velocity zero
Motor(s) remain in closed-loop
at velocity zero
Servo-ing – Jogging
(Closed-Loop mode)
Motor(s) decelerate to zero
velocity at Ixx15 rate
Motor(s) decelerate to zero
velocity at Ixx15 rate
Servo-ing – Running Program(s)
(Closed-Loop mode)
Aborts motion program(s)
and decelerate to zero
velocity at Ixx15 rate
Aborts motion program(s) and
decelerate to zero velocity
at Ixx15 rate