To delete an uplink-state group, use the
no uplink-state-group
group-id
command.
2 Assign a port or port-channel to the uplink-state group as an upstream or downstream interface.
UPLINK-STATE-GROUP mode
{upstream | downstream}
interface
For interface, enter one of the following interface types:
• 10 Gigabit Ethernet: enter
tengigabitethernet {
slot/port
[
/subport
] |
slot/port-
range
}
• For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE
then the slot/port information.
Where
port-range
and
port-channel-range
specify a range of ports separated by a dash (-) and/or
individual ports/port channels in any order; for example:
upstream tengigabitethernet 1/1-1/2,1/5,1/9,1/11-1/12
downstream port-channel 1-3,5
• A comma is required to separate each port and port-range entry.
To delete an interface from the group, use the
no {upstream | downstream}
interface
command.
3 Configure the number of downstream links in the uplink-state group that will be disabled (Oper Down
state) if one upstream link in the group goes down.
UPLINK-STATE-GROUP mode
downstream disable links {
number
| all}
•
number
: specifies the number of downstream links to be brought down. The range is from 1 to
1024.
•
all
: brings down all downstream links in the group.
The default is no downstream links are disabled when an upstream link goes down.
NOTE:
Downstream interfaces in an uplink-state group are put into a Link-Down state with an UFD-
Disabled error message only when all upstream interfaces in the group go down.
To revert to the default setting, use the
no downstream disable links
command.
4 (Optional) Enable auto-recovery so that UFD-disabled downstream ports in the uplink-state group
come up when a disabled upstream port in the group comes back up.
UPLINK-STATE-GROUP mode
downstream auto-recover
The default is auto-recovery of UFD-disabled downstream ports is enabled.
To disable auto-recovery, use the
no downstream auto-recover
command.
5 (Optional) Enter a text description of the uplink-state group.
UPLINK-STATE-GROUP mode
description
text
The maximum length is 80 alphanumeric characters.
Uplink Failure Detection (UFD)
1092
Содержание S4048T
Страница 1: ...Dell Configuration Guide for the S4048T ON System 9 10 0 1 ...
Страница 98: ... saveenv 7 Reload the system uBoot mode reset Management 98 ...
Страница 113: ...Total CFM Pkts 10303 CCM Pkts 0 LBM Pkts 0 LTM Pkts 3 LBR Pkts 0 LTR Pkts 0 802 1ag 113 ...
Страница 411: ...mode transit no disable Force10 Resilient Ring Protocol FRRP 411 ...
Страница 590: ...Figure 67 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 590 ...
Страница 591: ...Figure 68 Inspecting Configuration of LAG 10 on ALPHA Link Aggregation Control Protocol LACP 591 ...
Страница 594: ...Figure 70 Inspecting a LAG Port on BRAVO Using the show interface Command Link Aggregation Control Protocol LACP 594 ...
Страница 595: ...Figure 71 Inspecting LAG 10 Using the show interfaces port channel Command Link Aggregation Control Protocol LACP 595 ...
Страница 646: ...Figure 87 Configuring Interfaces for MSDP Multicast Source Discovery Protocol MSDP 646 ...
Страница 647: ...Figure 88 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 647 ...
Страница 648: ...Figure 89 Configuring PIM in Multiple Routing Domains Multicast Source Discovery Protocol MSDP 648 ...
Страница 653: ...Figure 91 MSDP Default Peer Scenario 2 Multicast Source Discovery Protocol MSDP 653 ...
Страница 654: ...Figure 92 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 654 ...
Страница 955: ...Figure 119 Single and Double Tag First byte TPID Match Service Provider Bridging 955 ...
Страница 1179: ...Figure 147 Create Hypervisor Figure 148 Edit Hypervisor Figure 149 Create Transport Connector Virtual Extensible LAN VXLAN 1179 ...