Figure 52. Installing bay 1 backplane
Next steps
1.
Install the bay intrusion switch
2. Connect all the cables to the backplane.
3.
Install the drive bay 1 bracket
.
4. Install the drives back into their original locations.
5.
6. If removed,
.
7. Follow the procedure listed in
After working inside your system
Removing the drive bay 2 backplane
Prerequisites
CAUTION:
Note the number of each drive and temporarily label them before you remove the drive so that you can
replace them in the same location.
1. Follow the safety guidelines listed in
2. Power off the system and all attached peripherals.
3. Disconnect the system from the electrical outlet, and disconnect the peripherals.
4.
5. Remove the
6. Remove the system from the rack and place it on an ESD work bench. For more information, see the
Rail Installation Guide
at
7.
.
NOTE:
Ensure that the drive bay is fully open to access the backplane.
8. Remove the drive bay 2 backplane brackets.
9. Disconnect all the cables from the backplane.
Steps
1. Using Phillips #2 screwdriver, remove all the screws securing the backplane.
70
Installing and removing system components