63
MCA
Pro
45/65/90/115
MCA-Pro ISM Rv.4.1 2/2017
4.11 Electrical Diagram
4. Installation
P
Main supply
GB
Combined Venturi and gas valve unit
PSU
Storage parameter
SCU
Extended control PCB
PUMP A
Boiler pump
OT
Thermostat
S
ON/OFF switch
HLS
Safety themostat
OS
Outdoor Temp. Sensor
FAN
Fan
RTS
Return sensor
WS
DHW sensor
IT
Ignition transformer
FTS
Flow sensor
PC
Connection Computer
E
Ignition power relay
PS
Pressure sensor
DIS
Display
FGTS
Flue gas temperature sensor
X1
X14
X13 X12
X3
X2 X4 X5
X6
X7
X8
X9
X10 X11
DIS
X14
1 10
1 10
X13
1
PC
OT
1 2
X12
3 4 5 6
OS
7 8
WS
9 1 0
SCU
SCU
X11
1 2 3 4 5 6
WH
GY
OR
RD
GN
YW
PWM
PUMP
BK
BK
1 2
X116
FTS
RTS
10
RD
1
BK
1
2
2
X115
9
BL
1
2
X114
PS
11
BK
BK
3 1
X112
4
X10
5
X111
BK
BK
BK
BK
1 2 3 4
PSU
15
13
7
8
6
12
1
2
BK
14
BK
2
4 3
X118
FGTS
3
HLS
X9
2 3 4 5
X91
BK
BK
BK
BK
1 2 4 5
FAN
1
BK
BK
1
2
X117
X8
1 2 3
PUMP A
BK
WH
GN
2 1 3
X81
3 1 2
X6
1 2 3
GN
RD
WH
GB
1
5
3
X21
IT
X5
2 3 4 1
E
BK
WH
GN
GY
1 2
3
X51
X4
1 2 3
X41
BK
WH
GN
3 1 2
FAN
X3
4
3 2 1
5
BR
BL
BR
BK
GN/
YW
3 1
4 2
X51
S
X2
1
3
2
P
120V, 60Hz
L
N
X1
1 2 3 4
GN
WH
BK
GN
Содержание MCA Pro 115
Страница 45: ...45 MCA Pro 45 65 90 115 MCA Pro ISM Rv 4 1 2 2017 4 Installation H D G C B A E I J F ...