DataKinetics DSC110 / DSC210 User Manual Issue 12
Page 74
7.13 Alarms
7.13.1 Alarm Class Set
ALCLS
Alarm Class Set
This command assigns an alarm class value to the specified fault code(s).
Syntax
ALCLS:CLA=,CODE=…;
Attributes
CONFIG
Example ALCLS:CLA=1,CODE=20;
7.13.2 Alarm Class Print
ALCLP
Alarm Class Print
This command gives a print-out of the fault codes belonging to a particular alarm
class. If the parameter CLA is omitted, all fault codes are printed out.
Syntax:
ALCLP[:CLA=];
Attributes: None.
Example: ALCLP;
ALCLP:CLA=2;
Output format
Alarm Fault Codes
CODE CLA TITLE
11 2 Processor1 fail
12 2 Processor2 fail
EXECUTED