12.3.3 Call Failure File Format:
1997-12-31,13:07:25,1425655050,13402000213,134,123,5218,21,31,6,1,1
1997-12-31,13:07:50,1234123456,13403008000,130,123,5219,21,30,16,20,34
1997-12-31,13:08:05,1425655050,13402000213,137,123,5220,22,21,0,0,134
Field Field
Example
Range
Description
1 Date
1997-12-31 yyyy-mm-dd
Date at time of failure
2
Time
13:07:25
hh:mm:ss
Time of failure
3
Calling Number
1425655050
Called party number
(after any POR
processing)
4
Called Number
13402000213
Digits
Called party number
(after any POR
processing)
5
Call Duration
134
Whole seconds
Call duration rounded to
the nearest second.
6 Equipment
reference
123
0 .. 999
Reference number of
the converter (user
configuration parameter)
7 Call
Sequence
Number
5218
1 .. N
Sequence number of
call for given day,
Allocated at time of call
termination.
8
Incoming circuit
group
21
1 .. n
CGRP number of the
incoming circuit group.
9
Incoming device
31
1 .. 31
DEV number of
incoming circuit within
the CGRP.
10
Outgoing circuit
group
6
0,1 .. n
CGRP number of the
outgoing circuit group
(set to 0 when the
outgoing group does not
exist).
11
Outgoing device
1
0 .. 31
DEV number of outgoing
circuit within the CGRP.
12 Cause
Release
Token
17
0 .. 255
Cause Value Internal
Token Representing the
reason for release.