7.24.6 Status PCM Print
STPCP
Status PCM Print
This command requests a status report of the PCMs. The PCM status is one of the
following:-
OK
- Normal operational state.
PCM Loss
- Loss of signal.
Sync Loss
- Loss of frame alignment.
RAI
- Remote alarm indication.
AIS
- Alarm indication signal.
(Note that some signalling software types currently support only Sync Loss and OK)
The Clock field is one of the following:-
OK
- The board is detecting a valid PCM signal which could potentially
be used for synchronisation.
Active - The board is detecting a valid PCM signal which is currently
providing synchronisation for the converter.
Not OK – The input to the board is not currently suitable for use as a
synchronisation source.
Fault - A fault has been detected on the board which prevents it being
used as a synchronisation source.
Syntax
STPCP;
Prerequisites None
Attributes CONFIG
Example STPCP;
Output format
PCM Status
PCM SYNCPRI PCM Status Clock
5-1 1 PCM Loss Fault
5-2 2 SYNC Loss Not OK
6-1 3 AIS Not OK
6-2 4 RAI OK
7-1 1 OK Active
7-2 1 OK OK
EXECUTED