7.18.12 CCS SS7 Signalling Link Print
C7SLP
CCS SS7 Signalling Link Print
This command is used to obtain a print-out of the attributes of SS7 Signalling
Link(s). If no link is specified, all initialised links are output.
Syntax
C7SLP:[C7LINK=…];
Attributes None.
Example C7SLP:C7LINK=1;
C7SLP;
Output format
Signalling Link Configuration
C7LINK EQU TS LS SLC M56K PCR
1 5-1 05-1-4 1 4 0 N
2 5-2 05-1-5 1 6 0 N
3 6-1 05-1-16 2 2 1 N