![DataKinetics DSC110 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/datakinetics/dsc110/dsc110_user-manual_511663056.webp)
DataKinetics DSC110 / DSC210 User Manual Issue 12
Page 56
SUBNET
Subnet mask for the network to which
the converter is connected specified
using dot notation:- www.xxx.yyy.zzz
www – 0:255
xxx - 0:255
yyy - 0:255
zzz - 0:255
Default =
255.255.255.0
SYNCPRI
The priority the PCM is given to provide
clock synchronisation.
0 – Indicates never provide clock
synchronisation
1 – Highest priority that PCM should
provide clock synchronisation.
32 – Lowest priority i.e. other PCMs
have precedence.
0:32
Default = 0
SYSID
System identity.
0:12 <text
character>
STS
A timeslot within a PCM interface on a
board used for monitoring for
monitoring information sent by the
monitored object.
Format: xx-y-zz
xx = board position (BPOS)
y = PCM within a board
zz = Timeslot
xx: 5:20
y: 1,2
zz: 1:31
SYSREF
The system reference number
0:999
Default = 0
TANS
The timer to be used when waiting for
answer.
T2,
T12,
T13,
T14
Default = T2
TEXT
Text string identities
Format x-y
x – Text id of string to sent on the
forward direction.
y – Text id of string to sent on the
backward direction.
x and y have the
range 0,1-30
TEXTID
Identifier for a text string
1-30
TIME
Time of day in format : xx:yy:zz
xx – 2 digit hour.
yy – 2 digit minute.
zz – 2 digit second.
xx – 00:23
yy – 00:59
zz – 00:59
TLO
Auto log off time (in minutes).
1:60
Default = 30
TLOW
Log off warning time (in minutes)
0:60
Default = 25