![DataKinetics DSC110 Скачать руководство пользователя страница 169](http://html1.mh-extra.com/html/datakinetics/dsc110/dsc110_user-manual_511663169.webp)
DataKinetics DSC110 / DSC210 User Manual Issue 12
Page 169
50
Board cong
A board has reached a congestion
threshold. Boards repeatedly entering
congestion indicate a need to increase the
dimensioning of the switch.
BPOS SYSTEM
51
TUP maint ind
Diagnostic event relating to NUP
functionality. Persistent events of this type
should be reported to DataKinetics.
NONE
52
TUP err ind
Diagnostic event relating to NUP
functionality. Persistent events of this type
should be reported to DataKinetics.
NONE
53
PCM mismatch
The PCMTYPE setting is inconsistent with
the hardware settings on the board.
PCM 0 SYSTEM
54
DP4 event
Diagnostic event relating to DPNSS
functionality. Persistent events of this type
should be reported to DataKinetics.
NONE
55
DP3 event
Diagnostic event relating to DPNSS
functionality. Persistent events of this type
should be reported to DataKinetics.
NONE
56
DP2 event
Diagnostic event relating to DPNSS
functionality. Persistent events of this type
should be reported to DataKinetics.
NONE
57
DLC failure
Failure of 1 or more DLCs on a DPNSS
signalling link.
ASLINK 0
SIG
58
ANN event
Diagnostic event relating to Announcement
functionality. Persistent events of this type
should be reported to DataKinetics.
NONE
59
ANN error
Diagnostic event relating to Announcement
functionality. Persistent events of this type
should be reported to DataKinetics.
NONE
60
Announcement failure
The announcement WAV file has become
invalid. The indicated ANNC should be
removed.
ANNC 0 NONE
6
1
SW mismatch
The system has only partially been
upgraded and a full software update is
required. The system is running in ‘safe’
mode running limited management software.
No circuits have been brought into service.
0 0
SYSTEM
62
C7 link Cong
A SS7 signalling link is encountering
congestion.
C7LINK 0
SIG