7.8 Command Responses
The converter does not, in general, produce output unless in response to an
operator command. The only exception to this is the auto log off warning message
and the log off message (when log off is initiated automatically).
The auto log off warning message is as follows:
WARNING: Auto log off imminent!
When a syntactically correct command has been issued to the converter,
acceptance is indicated by the Command Executed output as follows:
EXECUTED
An invalid command will not be acted upon. The converter indicates command
rejection by issuing one of the following responses. Note that only the first error
detected in a command will be indicated.
RESPONSE
REASON FOR REJECTION
UNACCEPTABLE COMMAND
The command is valid but not in the current state of the
equipment (e.g. changing a signalling link configuration
without blocking).
UNKNOWN COMMAND
The command is not recognised.
NO SYSTEM RESOURCES
The requested command cannot be executed due to
unavailable system resources.
INVALID PARAMETER NAME
A parameter name has been entered which is not valid for this
command.
EXTRA PARAMETERS
Too many parameters have been entered.
MISSING PARAMETER
A required parameter has not been input.
INCONSISTENT PARAMETER
The parameters input are not valid together for the command.
MISSING DATA
A parameter has no data.
INCONSISTENT DATA
The values of parameters are inconsistent with each other or
with data already entered into the system.
RANGE ERROR
The value assigned to a numeric parameter is outside the
valid range.
INVALID INFORMATION
GROUPING
The type of information grouping used in the input of the
parameter value is not valid.
INVALID INDICATOR
This command contains a ‘format character’ (‘:’, ‘;’, etc.)
which is not valid for this command.
GENERAL ERROR
Command unable to execute due to external error (e.g.
Missing or write protected floppy disk).
INTERNAL ERROR
Command failed to complete due to internal error.
INVALID INFORMATION
UNIT
The value entered for a parameter is not valid for that
parameter.
UNKNOWN SEPARATOR
The character used to separate two parameters is not
recognised.
Table 7.1 Command Rejection Responses