DataKinetics DSC110 / DSC210 User Manual Issue 12
Page 154
7.24.5 Status Device Print
STDEP
Status Device Print
This command requests a status of a device.
If a device has not been initiated, attached to a group or unblocked a status will not
be given. The CIC is only given for SS7 devices.
If a PAGE parameter is specified then that particular page of data will be output. In
no page is specified then page 1 will be output. For DPNSS page 1 will be used to
provide status for real circuits while page 2 will be used to provide status for virtual
circuits.
Definitions for device status:-
CALL STATE: - The current call control state for a device .
PROTOCOL STATE: - The current protocol state for a device.
IC_SEIZED - Incoming circuit has been seized
IC_WROUTE - Initial address message received. Awaiting further information
before routing.
IC_SETUP
- Incoming side, call has routed and is awaiting alerting.
OG_SETUP - Outgoing side, call has routed and is awaiting alerting.
IC_ALERT
- Incoming side awaiting answer.
OG_ALERT - Outgoing side awaiting answer.
CONNECT
- Call answered and in progress.
RELEASE
- Call has been released and is awaiting release completion.
L2 STATUS:- The Status of Level 2 (for DPNSS).
BLOCKING STATUS
RS – Device has blocked while undergoing circuit reset.
LM – Device has been inhibited by MML.
LH – Device has been locally hardware blocked due to PCM Loss.
PM – Device has been maintenance blocked by its partner circuit in circuit
mapping.
PH – Device has been hardware blocked partner circuit in circuit mapping.
RM – Device has been remotely maintenance blocked.
RH – Device has been remotely hardware blocked.
Syntax
STDEP:CGRP=,[DEV=,][PAGE=,];
STDEP:CGRP=,[CIC=,][PAGE=,];
Prerequisites
The circuit group should already have been initiated.
Page 2 can only be specified for DPNSS circuits.
Attributes None.
Example STDEP:CGRP=1;
STDEP:CGRP=5,CIC=123;