DataKinetics DSC110 / DSC210 User Manual Issue 12
Page 131
7.22.5 Remote Data Centre Continuous Record Change
RDCRC
Remote Data Centre Continuous Record Change
This command changes the parameters for a continuous record collection for
which collected data is transferred via Ethernet to a Remote Data Centre (RDC).
Continuous records can be specified for billing or call failures.
The period is the maximum amount of time allowed before the transfer of a block
of continuous records must be performed.
The label will be used as the directory name on the remote data centre the files are
written to.
Data can be added/deleted from the continuous records using the RDCDI/RDCDE
commands.
Prerequisites
The record must already be initiated.
If specified RDC1 must already be initiated.
If specified RDC2 must already be initiated
If specified RDC2 must not equal RDC1.
Limitations
Before transfer to a RDC can take place the directory, represented by the label,
must exist on the remote site.
PERIOD must be in the range 30 seconds to 30 minutes.
Syntax RDCRC:RECORD=,[PERIOD=,][MINREC=,][RDC1=,][RDC2=,][LABEL=];
Attributes CONFIG,
RDC
Example RDCRC:RECORD=1,PERIOD=00:05:00,MINREC=100,
RDC1=1,LABEL=BILLING;