M.A.Ch.10/100 Diagnostic Analyzer 09/00
13
General Tab Screen With Different Cable Values Displayed
Available cable values are:
•
Calibrated (Allows you to choose your own specific cable for each individual
site. The information about your calibrated cable is stored in your site specific
data.)
•
Category 5
•
Category 3
•
10Base-T
•
ISO 11801 Class C
•
ISO 11801 Class D
4. If you use a particular type of cable, and you would like to determine your own
calibration value for a given cable, use the calibration feature in this control group to
create you own customized value by clicking
Calibrate.
NVP Calibration Screen
5. Enter the actual length of the cable and click
Start.
The M.A.Ch.10/100 calculates
the NVP for this cable.
6. Under
Units
, select either
Feet
or
Meters
to use in measurements being displayed.
7. Select the desired
Monitor Report Rate
. This value is used to determine how often
data is collected from the M.A.Ch.10/100 hardware. This value can be set from 2
seconds up to 10 seconds.