P o l l i n g t h e T C U
20
Pump #3 Stop
Activates the alarm any time Pump 3 is running and stops without control
by the PCU
21
Float Sequence
Allows telemetry to sense float sequence fault and activate the alarm
22
Level Transducer
Detects malfunction of a Transducer and activates the alarm
23
Backup Memory
Detects failure of the EEPROM backup memory and activates the alarm
24
AC Power
Detects the presence of AC Power and activates the Alarm when absent
25
DC Bias
Detects the presence of isolated DC bias and activates the alarm when
absent
26
Low Well Level
Detects whether the Low Level sensor is OK or in the FAULT (Emergency
Low) state
27
High Well Level
Detects whether the High Level sensor is OK or in the HIGH state
31
HOA Switch 1
Detects position of HOA switch 1 and activates alarm for “Hand” position
32
HOA Switch 1
Detects position of HOA switch 1 and activates alarm for “Off” position
33
HOA Switch 1
Detects position of HOA switch 1 and indicates the “Auto” position
34
HOA Switch 2
Detects position of HOA switch 2 and activates alarm for “Hand” position
35
HOA Switch 2
Detects position of HOA switch 2 and activates alarm for “Off” position
36
HOA Switch 2
Detects position of HOA switch 2 and indicates the “Auto” position
37
HOA Switch 3
Detects position of HOA switch 3 and activates alarm for “Hand” position
38
HOA Switch 3
Detects position of HOA switch 3 and activates alarm for “Off” position
39
HOA Switch 3
Detects position of HOA switch 3 and indicates the “Auto” position
40
Auxiliary Output
Detects whether the auxiliary output is in the OFF or ON state
41
Alarm Horn Status
Detects whether the alarm horn is in the OFF or RINGING state
42
Alarm Light Status
Detects whether the alarm light is in the FLASHING or OFF state
43
Any Pump
Indicates the run status of any pump
44
PCU Configuration
Detects if the Local Configuration has been updated and activates the alarm
for UPDATE.
49a
Analog Input
Settings for Analog Input when used with analog-current type transducer
49b
Analog Input
Settings for Analog Input when used with analog-voltage type transducer
50
Phase AB Voltage
Settings for Phase AB Voltage for phase monitor
51
Phase AC Voltage
Settings for phase AC voltage for phase monitor
52
Well Level
Calibration points for displaying Well Level
58
Pump #1 Override
In the OVERRIDE state, allows telemetry to control Pump 1 and bypass the
TCU
59
Pump #2 Override
In the OVERRIDE state, allows telemetry to control Pump 2 and bypass the
TCU
60
Pump #3 Override
In the OVERRIDE state, allows telemetry to control Pump 3 and bypass the
TCU
61
Aux. Output Override
In the OVERRIDE state, allows telemetry to control the Auxiliary Output
62
Alarm Horn Override
In the OVERRIDE state, allows telemetry to control the Alarm Horn
63
Alarm Light Disable
In the OVERRIDE state, allows telemetry to control the Alarm Light
64
Station Disable
In the DISABLED state, allows telemetry to cut power to all pump motors
65
Pump #1 Disable
In the DISABLED state, allows telemetry to cut power to Pump 1
66
Pump #2 Disable
In the DISABLED state, allows telemetry to cut power to Pump 2
67
Pump #3 Disabe
In the DISABLED state, allows telemetry to cut power to Pump 3
68
Aux. Output Disable
Detects if the auxiliary output is in the AUTO or DISABLED state
Содержание TCU800
Страница 1: ...Installation and Operation Manual T C U 8 0 0 Data Flow Systems Inc P r e l i m i n a r y ...
Страница 2: ...Intentionally left blank ...
Страница 4: ...D a t a F l o w S y s t e m s I n c Intentionally left blank ...
Страница 8: ...ii Intentionally left blank ...
Страница 10: ...ii Intentionally left blank ...
Страница 49: ...39 S e t u p Externally Powered Non submersible Transducer TCU Powered Non submersible Transducer ...
Страница 56: ...46 C h a p t e r 5 Quick View Analog View Pump Statistics ...
Страница 57: ...47 U s e r I n t e r f a c e Alarms Settings Screen 1 Settings Screen 2 ...
Страница 58: ...48 C h a p t e r 5 Advanced Settings About ...
Страница 77: ...67 O p e r a t i n g P r o c e d u r e s TCU Installed in Existing Control Panel ...
Страница 87: ...77 M o d b u s S u p p o r t Figure 1 Figure 2 Figure 3 ...
Страница 92: ...82 D a t a F l o w S y s t e m s I n c Appendix ...
Страница 157: ...147 D a t a F l o w S y s t e m s I n c ...
Страница 158: ...148 D a t a F l o w S y s t e m s I n c ...
Страница 159: ...149 D a t a F l o w S y s t e m s I n c ...
Страница 160: ......
Страница 161: ...151 D a t a F l o w S y s t e m s I n c ...
Страница 162: ...Data Flow Systems Inc 605 N John Rodes Blvd Melbourne Florida 32934 321 259 5009 www dataflowsys com ...