C h a p t e r 2
Compatibility
Please note that the PCU, PCU TAC Pack, SCU, and SCU TAC Pack are not “upward” compatible with the TCU800.
DFS’ Sales Department can provide assistance with ensuring that your system has appropriate replacement units on hand.
Contact DFS’ Sales Department (321-259-5009 or [email protected]) for more information.
When comparing the TCU001 and the TCU800, use the following table to review features that have been removed,
replaced, and added to the TCU800.
Custom Logic
Capable of running custom programming. Supports ladder logic or scripting that re-
places the default pump control application. Contact DFS for more information.
Connectorized Wire
Terminals
Four connectorized wire terminals allow servicing or replacement of the unit without
disconnecting wires.
Mounting Options
Mounting options allow the TCU to be mounted to a front panel as well as mounted
flush against or stood off from the back plate of a control panel.
Legacy TCU001 Operation
The TCU800 is backward compatible with the TCU001. Existing TCU001
configurations can be transferred to the TCU800. For detailed instructions, see the
compatibility chart below.
Enclosure
Anodized aluminum, sealed and shielded when connected to Earth ground via
grounding screw.
Inputs/Outputs
18 Digital Inputs supporting voltage-driven signals (Pulse input can be used with
pulse-type flow meters and rain gauges)
6 Digital Outputs (4 solid-state relays designed to drive inductive loads & 2 electrome-
chanical relays designed to drive horn and light)
4 Analog Inputs for well level and auxiliary measurement
Содержание TCU800
Страница 1: ...Installation and Operation Manual T C U 8 0 0 Data Flow Systems Inc P r e l i m i n a r y ...
Страница 2: ...Intentionally left blank ...
Страница 4: ...D a t a F l o w S y s t e m s I n c Intentionally left blank ...
Страница 8: ...ii Intentionally left blank ...
Страница 10: ...ii Intentionally left blank ...
Страница 49: ...39 S e t u p Externally Powered Non submersible Transducer TCU Powered Non submersible Transducer ...
Страница 56: ...46 C h a p t e r 5 Quick View Analog View Pump Statistics ...
Страница 57: ...47 U s e r I n t e r f a c e Alarms Settings Screen 1 Settings Screen 2 ...
Страница 58: ...48 C h a p t e r 5 Advanced Settings About ...
Страница 77: ...67 O p e r a t i n g P r o c e d u r e s TCU Installed in Existing Control Panel ...
Страница 87: ...77 M o d b u s S u p p o r t Figure 1 Figure 2 Figure 3 ...
Страница 92: ...82 D a t a F l o w S y s t e m s I n c Appendix ...
Страница 157: ...147 D a t a F l o w S y s t e m s I n c ...
Страница 158: ...148 D a t a F l o w S y s t e m s I n c ...
Страница 159: ...149 D a t a F l o w S y s t e m s I n c ...
Страница 160: ......
Страница 161: ...151 D a t a F l o w S y s t e m s I n c ...
Страница 162: ...Data Flow Systems Inc 605 N John Rodes Blvd Melbourne Florida 32934 321 259 5009 www dataflowsys com ...