5.1.3 1-** Load / Motor
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
1-0* General Settings
1-00
Configuration Mode
ExpressionLimit
All set-ups
TRUE
-
Uint8
1-03
Torque Characteristics
[3] Auto Energy Optim. VT
All set-ups
TRUE
-
Uint8
1-06
Clockwise Direction
[0] Normal
All set-ups
FALSE
-
Uint8
1-1* Motor Selection
1-10
Motor Construction
[0] Asynchron
All set-ups
FALSE
-
Uint8
1-1* VVC+ PM
1-14
Damping Gain
120 %
All set-ups
TRUE
0
Int16
1-15
Low Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-16
High Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-17
Voltage filter time const.
ExpressionLimit
All set-ups
TRUE
-3
Uint16
1-2* Motor Data
1-20
Motor Power [kW]
ExpressionLimit
All set-ups
FALSE
1
Uint32
1-21
Motor Power [HP]
ExpressionLimit
All set-ups
FALSE
-2
Uint32
1-22
Motor Voltage
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-23
Motor Frequency
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-24
Motor Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
1-25
Motor Nominal Speed
ExpressionLimit
All set-ups
FALSE
67
Uint16
1-28
Motor Rotation Check
[0] Off
All set-ups
FALSE
-
Uint8
1-29
Automatic Motor Adaptation (AMA)
[0] Off
All set-ups
FALSE
-
Uint8
1-3* Adv. Motor Data
1-30
Stator Resistance (Rs)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-31
Rotor Resistance (Rr)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-35
Main Reactance (Xh)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
1-36
Iron Loss Resistance (Rfe)
ExpressionLimit
All set-ups
FALSE
-3
Uint32
1-37
d-axis Inductance (Ld)
ExpressionLimit
All set-ups
FALSE
-6
Int32
1-39
Motor Poles
ExpressionLimit
All set-ups
FALSE
0
Uint8
1-40
Back EMF at 1000 RPM
ExpressionLimit
All set-ups
FALSE
0
Uint16
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
100 %
All set-ups
TRUE
0
Uint16
1-51
Min Speed Normal Magnetising [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
1-52
Min Speed Normal Magnetising [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
1-58
Flystart Test Pulses Current
30 %
All set-ups
FALSE
0
Uint16
1-59
Flystart Test Pulses Frequency
200 %
All set-ups
FALSE
0
Uint16
1-6* Load Depen. Setting
1-60
Low Speed Load Compensation
100 %
All set-ups
TRUE
0
Int16
1-61
High Speed Load Compensation
100 %
All set-ups
TRUE
0
Int16
1-62
Slip Compensation
0 %
All set-ups
TRUE
0
Int16
1-63
Slip Compensation Time Constant
ExpressionLimit
All set-ups
TRUE
-2
Uint16
1-64
Resonance Dampening
100 %
All set-ups
TRUE
0
Uint16
1-65
Resonance Dampening Time Constant
5 ms
All set-ups
TRUE
-3
Uint8
1-66
Min. Current at Low Speed
ExpressionLimit
All set-ups
TRUE
0
Uint8
1-7* Start Adjustments
1-71
Start Delay
0.0 s
All set-ups
TRUE
-1
Uint16
1-72
Start Function
ExpressionLimit
All set-ups
TRUE
-
Uint8
1-73
Flying Start
[0] Disabled
All set-ups
TRUE
-
Uint8
1-77
Compressor Start Max Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
1-78
Compressor Start Max Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
1-79
Compressor Start Max Time to Trip
5.0 s
All set-ups
TRUE
-1
Uint8
Parameter Lists
VLT
®
HVAC Drive Programming Guide
MG.11.CC.02 - VLT
®
is a registered Danfoss trademark
209
5
5