Swimming Mode Operation
29
If the Clock Is Still Counting
When the running time is counting, press
[EDIT]
to make corrections to the times in the
current race memory. Use
[EDIT]
to insert a backup or a stopwatch time if there was a
problem with a touchpad. Distinguished from touchpad times on the LCD and printouts,
edited times indicate an “E” if manually entered or a “B” if it is a backup time.
1 2 3 4 5 6 7 8 9 10
OK OK 00 -- E
LN 6 0.00*
The top line of the left and middle LCDs display the current lane status. An arrow by the
lane also indicates which lane is currently selected for editing. The following table defines
what each symbol means.
Symbol
Definition
^
There is an error in the lane and the data needs to be edited.
DQ
Indicates the person in the lane has been disqualified.
E
Indicates an edited time.
--
Lane has been turned off.
OK
All data is correct.
The bottom line of the left LCD shows the lane and time, and the center LCD shows the
backup time. The right LCD shows the options available for editing the lane times. Press
[1]
to skip to the next lane. Press
[2]
to use the backup time. Press
[3]
to edit the lanes
time. Press
[4]
to turn the lane ON/OFF.
Disqualification (DQ)
Before the meet, the timing operator should clarify with the meet referee if he/she wants
the swimmers to be disqualified on the timer. Clarification of this is important for results to
be properly ranked on the printouts and meet management software which will show as
a DQ on the scoreboard.
Press
[DQ]
(disqualification) and
[LANE ON/OFF]
for the desired lane (or press the lane
number on the numeric keypad) and press
[ENTER]
. The DQ operation is normally done
at the conclusion of the race, after the officials have ruled on the situation that caused
the swimmer to be disqualified. On exit from the DQ command, the scoreboard is
automatically updated and any subsequent printouts will show the revised placing.
The DQ operation shown on the right LCD as illustrated,
can be done at any point in the race and does not affect
arming or recording of times for the lane. Press the same
lane number again while in the DQ command to re-qualify
the swimmer and the original status indicator is returned.
^[OK OK E OK
BACKUP-- 0:00.00
1-SKIP 2-BACKUP
3-EDIT 4-ON/OFF
DISQUALIFY (DQ)
LANE NUMBER:10
Содержание OMNISPORT 2000
Страница 10: ...This page intentionally left blank...
Страница 150: ...This page intentionally left blank...
Страница 154: ...DAKTRONICS DAKTRONICS DAKTRONICS DAKTRONICS DAKTRONICS...
Страница 156: ......
Страница 158: ......
Страница 162: ...This page intentionally left blank...
Страница 163: ...LL 2549 R02 SWIMMING...
Страница 164: ...LL 2566 REV 02 DIVING...
Страница 165: ...LL 2569 REV 02 WATER POLO HOME SHOT TIME GUEST GAME TIME...
Страница 166: ...TRACK LL 2573 REV 03...
Страница 167: ...LL 2581 REV 01 PACE CLOCK...
Страница 168: ...This page intentionally left blank...
Страница 176: ...This page intentionally left blank...
Страница 178: ...This page intentionally left blank...
Страница 180: ...This page intentionally left blank...