SiBE37-701
Table of Contents
iii
Remote Controller Service Mode .........................................................243
Remote Controller Self-Diagnosis Function .........................................245
3. Troubleshooting by Indication on the Remote Controller ....................252
Error of External Protection Device............................252
PC Board Defect ........................................................253
Malfunction of Drain Level Control System (S1L) ......254
Fan Motor (M1F) Lock, Overload...............................256
” Indoor Unit : Malfunction of Indoor Unit Fan Motor........................258
” Indoor Uint : Overload / Overcurrent /
Lock of Indoor Unit Fan Motor..............................................................259
Malfunction of Swing Flap Motor (M1S).....................260
Electronic Expansion Valve Malfunction / Dust Clogging ..............262
Malfunction of Electronic Expansion Valve Coil.........264
Drain Level above Limit .............................................266
Malfunction of Capacity Determination Device ..........267
Malfunction of Thermistor (R2T) for
Malfunction of Thermistor (R3T) for Gas Pipes .........269
Malfunction of Thermistor (R1T) for Suction Air.........270
Malfunction of Thermostat Sensor in
PC Board Defect .....................................................272
Actuation of High Pressure Switch..........................273
Actuation of Low Pressure Sensor..........................275
Outdoor Unit: Inverter Compressor Motor Lock.............................277
Outdoor Unit: STD Compressor Motor Overcurrent/Lock..............279
Outdoor Unit: Malfunction of Outdoor Unit Fan Motor ...................280
Electronic Expansion Valve (Y1E~Y5E)...............................................283
Abnormal Discharge Pipe Temperature..................285
Outdoor Unit: Refrigerant Overcharged.........................................287
” Outdoor Unit : Malfunction of BS Unit
Electronic Expansion Valve..................................................................288
Outdoor Unit: Abnormal Outdoor Fan Motor Signal ......................290
Malfunction of Thermistor (R1T) for Outdoor Air.....292
Outdoor Unit: Current Sensor Malfunction ....................................293
Malfunction of Discharge Pipe Thermistor
(R31T, R32T, R33T).............................................................................294
Malfunction of Temperature Sensor for
Heat Exchanger Gas (R2T or R11T)....................................................295
Malfunction of Thermistor (R8T or R10T) for
Malfunction of Thermistor (R4T or R12T) for
Outdoor Unit Heat Exchanger ..............................................................297
Malfunction of Liquid Pipe Thermistor 1
(R6T, R9T or R14T) .............................................................................298
Malfunction of Liquid Pipe Thermistor 2
Malfunction of Subcooling Heat Exchanger Gas Pipe
Thermistor (R5T or R13T) ....................................................................300
Malfunction of High Pressure Sensor......................301
Содержание VRV III REYQ10PY1B
Страница 1: ...REYQ8 48PY1B R 410A Heat Recovery 50Hz SiBE37 701 ...
Страница 111: ...Refrigerant Flow for Each Operation Mode SiBE37 701 100 Refrigerant Circuit ...
Страница 252: ...SiBE37 701 Troubleshooting by Remote Controller Troubleshooting 241 ...
Страница 395: ...Piping Diagrams SiBE37 701 384 Appendix 1 Piping Diagrams 1 1 Outdoor Unit REYQ8P 10P 12P 3D058154B S1NPH S2NPL ...
Страница 396: ...SiBE37 701 Piping Diagrams Appendix 385 REYQ14P 16P 3D058153B S2NPL S1NPH ...
Страница 397: ...Piping Diagrams SiBE37 701 386 Appendix REMQ8P 3D057743 ...
Страница 398: ...SiBE37 701 Piping Diagrams Appendix 387 REMQ10P 12P 3D057742 ...
Страница 399: ...Piping Diagrams SiBE37 701 388 Appendix REMQ14P 16P 3D057741 ...
Страница 400: ...SiBE37 701 Piping Diagrams Appendix 389 1 2 Indoor Unit FXFQ P ...
Страница 405: ...Piping Diagrams SiBE37 701 394 Appendix 1 3 BS Unit 4D057985A ...
Страница 414: ...SiBE37 701 Wiring Diagrams for Reference Appendix 403 2 3 Indoor Unit FXFQ20P 25P 32P 40P 50P 63P 80P 100P 125PVEB ...
Страница 415: ...Wiring Diagrams for Reference SiBE37 701 404 Appendix FXZQ20M 25M 32M 40M 50MV1 ...
Страница 416: ...SiBE37 701 Wiring Diagrams for Reference Appendix 405 FXCQ20M 25M 32M 63MV3 ...
Страница 417: ...Wiring Diagrams for Reference SiBE37 701 406 Appendix FXCQ40M 50M 80M 125MV3 ...
Страница 420: ...SiBE37 701 Wiring Diagrams for Reference Appendix 409 FXDQ20M 25MV3 ...
Страница 421: ...Wiring Diagrams for Reference SiBE37 701 410 Appendix FXSQ20M 25M 32M 40M 50M 63MV3 ...
Страница 422: ...SiBE37 701 Wiring Diagrams for Reference Appendix 411 FXSQ80M 100M 125MV3 ...
Страница 447: ...Example of connection SiBE37 701 436 Appendix ...
Страница 453: ...Method of Checking the Inverter s Power Transistors and Diode Modules SiBE37 701 442 Appendix ...
Страница 467: ...SiBE37 701 iv Index ...